Initial Results of an Intercomparison of AMS-Based Atmospheric 14CO2 Measurements

Authors :
Jocelyn Turnbull
Shuji Aoki
Scott J. Lehman
Toshio Nakamura
Hitoshi Mukai
Sanne W.L. Palstra
Takakiyo Nakazawa
Yukio Terao
Chad Wolak
Andrew Smith
Miyuki Kondo
Gregory Dunn
Ralph Keeling
John Southon
Masao Uchida
C. E. Allison
Anita T. Aerts-Bijma
Heather Graven
Brian LaFranchi
T. P. Guilderson
John B. Miller
Xiaomei Xu
Harro A. J. Meijer
Isotope Research
Source :
Radiocarbon, 55(2-3), 1475-1483. UNIV ARIZONA DEPT GEOSCIENCES
Publication Year :
2013
Publisher :
UNIV ARIZONA DEPT GEOSCIENCES, 2013.

Abstract

This article presents results from the first 3 rounds of an international intercomparison of measurements of Delta(CO2)-C-14 in liter-scale samples of whole air by groups using accelerator mass spectrometry (AMS). The ultimate goal of the intercomparison is to allow the merging of Delta(CO2)-C-14 data from different groups, with the confidence that differences in the data are geophysical gradients and not artifacts of calibration. Eight groups have participated in at least 1 round of the intercomparison, which has so far included 3 rounds of air distribution between 2007 and 2010. The comparison is intended to be ongoing, so that: a) the community obtains a regular assessment of differences between laboratories; and b) individual laboratories can begin to assess the long-term repeatability of their measurements of the same source air. Air used in the intercomparison was compressed into 2 high-pressure cylinders in 2005 and 2006 at Niwot Ridge, Colorado (USA), with one of the tanks "spiked" with fossil CO2, so that the 2 tanks span the range of Delta(CO2)-C-14 typically encountered when measuring air from both remote background locations and polluted urban ones. Three groups show interlaboratory comparability within 1 parts per thousand for ambient level Delta(CO2)-C-14. For high CO2/low Delta(CO2)-C-14 air, 4 laboratories showed comparability within 2 parts per thousand. This approaches the goals set out by the World Meteorological Organization (WMO) CO2 Measurements Experts Group in 2005. One important observation is that single-sample precisions typically reported by the AMS community cannot always explain the observed differences within and between laboratories. This emphasizes the need to use long-term repeatability as a metric for measurement precision, especially in the context of long-term atmospheric monitoring.

Details

Language :
English
ISSN :
00338222
Volume :
55
Issue :
2-3
Database :
OpenAIRE
Journal :
Radiocarbon
Accession number :
edsair.doi.dedup.....d1efe178ceb17c9ec37f35df17da2eda