Back to Search
Start Over
Hairpin DNA assisted dual-ratiometric electrochemical aptasensor with high reliability and anti-interference ability for simultaneous detection of aflatoxin B1 and ochratoxin A
- Source :
- Biosensorsbioelectronics. 174
- Publication Year :
- 2020
-
Abstract
- The simultaneous detection of multiple mycotoxins in grains is significant due to the enhanced toxicity induced by their synergistic effects. In this work, a dual-ratiometric electrochemical aptasensing strategy for the simultaneous detection of aflatoxin B1 (AFB1) and ochratoxin A (OTA) was developed. Here, an anthraquinone-2-carboxylic acid (AQ)-labelled complementary DNA (cDNA) was used to provide separate and specific binding sites to assemble the ferrocene-labelled AFB1 aptamer (Fc-Apt1) and methylene blue-labelled OTA aptamer (MB-Apt2). The target-induced current ratios of IFc/IAQ and IMB/IAQ were then used to quantitatively relate to AFB1 and OTA, respectively. Following this principle, two types of aptasensors involving the hairpin DNA (hDNA) and linear single-stranded DNA (ssDNA) as the cDNA were fabricated for performance comparisons. The results revealed that hairpin DNA with a rigid 2D structure can greatly improve the assembly and recognition efficiency of the sensing interface, which makes the hDNA-based aptasensor possess high sensitivity, reliability and anti-interference ability. The hDNA-based aptasensor exhibited a detection range of 10-3000 pg mL−1 for AFB1 and 30-10000 pg mL−1 for OTA, respectively, with no observable cross-reactivity. Furthermore, the aptasensor was applied to analyze corn and wheat samples, and the reliability was validated by HPLC-MS/MS. Our work has presented a novel way for fabricating a high-performance aptasensor for simultaneous detection of multiple mycotoxins.
- Subjects :
- Ochratoxin A
Aflatoxin
Aflatoxin B1
Aptamer
Biomedical Engineering
Biophysics
02 engineering and technology
Biosensing Techniques
Electrochemistry
Interference (wave propagation)
01 natural sciences
chemistry.chemical_compound
Limit of Detection
Tandem Mass Spectrometry
Complementary DNA
Chromatography
Chemistry
010401 analytical chemistry
Reproducibility of Results
General Medicine
DNA
Electrochemical Techniques
Aptamers, Nucleotide
021001 nanoscience & nanotechnology
Ochratoxins
0104 chemical sciences
Gold
0210 nano-technology
Biotechnology
Subjects
Details
- ISSN :
- 18734235
- Volume :
- 174
- Database :
- OpenAIRE
- Journal :
- Biosensorsbioelectronics
- Accession number :
- edsair.doi.dedup.....d218fda70c5d0e7a03ca82d3e62c4cc9