Back to Search
Start Over
The Role of Spleen and Liver Elastography and Color-Doppler Ultrasound in the Assessment of Transjugular Intrahepatic Portosystemic Shunt Function
- Source :
- Ultrasound in Medicine & Biology. 46:1641-1650
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- The reference standard for assessing transjugular intrahepatic portosystemic shunt (TIPS) function is venography with portosystemic pressure gradient (PPG) measurement. This procedure is invasive and expensive; thus, we assessed the feasibility, reproducibility and diagnostic accuracy of color-Doppler ultrasound (CDUS) and spleen and liver stiffness (LS) measurements for identifying TIPS dysfunction. Twenty-four patients (15 undergoing TIPS placement and nine undergoing TIPS revision) consecutively underwent CDUS examination and LS and spleen stiffness (SS) determination by transient elastography (TE) and point shear-wave elastography (pSWE). All parameters were taken before TIPS placement/revision (1–15 d before) and 24 h after, just before revision by venography. pSWE inter-observer agreement was assessed by intra-class correlation coefficient (ICC). CDUS and elastographic data were correlated (Pearson coefficient) with pressure gradients (hepatic venous pressure gradient [HVPG], PPG). Main determinants of TIPS dysfunction were investigated by linear regression. Forty-nine paired examinations were performed in total: 49 (100%) SS reliable measurements by pSWE and 38 (88%) by TE. The ICC for pSWE values was 0.90 (95% confidence interval [CI] 0.81‒0.94). SS values significantly correlated with HVPG and PPG (R = 0.51, p = 0.01). The area under the Receiver-Operating Characteristic (AUROC) curve of SS for diagnosing TIPS dysfunction was 0.86 (95% CI 0.70‒0.96) using a 25 kPa cutoff. At multivariate analysis, the flow direction of the intrahepatic portal vein branches and SS values were independently associated to TIPS dysfunction. The intrahepatic portal vein branches flow direction and SS value are two simple, highly sensitive parameters accurately excluding TIPS dysfunction. SS measurement by pSWE is feasible, reproducible and both positively and significantly correlates with HVPG and PPG values.
- Subjects :
- Adult
Male
Acoustics and Ultrasonics
medicine.medical_treatment
Portal venous pressure
Biophysics
Venography
030218 nuclear medicine & medical imaging
Young Adult
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Ultrasonography, Doppler, Color
Aged
Aged, 80 and over
Reproducibility
Radiological and Ultrasound Technology
medicine.diagnostic_test
business.industry
Ultrasound
Middle Aged
Confidence interval
Treatment Outcome
Liver
Elasticity Imaging Techniques
Female
030211 gastroenterology & hepatology
Elastography
Portasystemic Shunt, Transjugular Intrahepatic
Nuclear medicine
business
Transient elastography
Transjugular intrahepatic portosystemic shunt
Spleen
Subjects
Details
- ISSN :
- 03015629
- Volume :
- 46
- Database :
- OpenAIRE
- Journal :
- Ultrasound in Medicine & Biology
- Accession number :
- edsair.doi.dedup.....d22bdbeaaa01bcd286ea69fc39a6167f
- Full Text :
- https://doi.org/10.1016/j.ultrasmedbio.2020.04.007