Back to Search Start Over

Enhancing the extraction of laser-ionized beams from an arc discharge ion source volume

Authors :
Shane Wilkins
B. A. Marsh
Sebastian Rothe
P. Van Duppen
Thomas Elias Cocolios
Thierry Stora
K. Chrysalidis
V. N. Fedosseev
Mark Huyse
B. Crepieux
J.P. Ramos
Richard Catherall
Y. Martinez Palenzuela
J. Ballof
T. Day Goodacre
P. Larmonier
J.D.A. Smith
Source :
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms

Abstract

© 2018 The Author(s) The Versatile Arc Discharge and Laser Ion Source (VADLIS) is a recently established ion source for the CERN-ISOLDE radioactive ion beam facility. It offers either electron-impact ionization (VADIS-mode) or resonance laser ionization (RILIS-mode). The choice of operating mode depends on the element of interest or the required beam purity. Particle-in-cell simulations using the VSim software show that the ion extraction efficiency of the VADLIS in RILIS-mode can be improved if it is equipped with an insulated extractor plate, to which an optimal voltage can be applied. This enables optimization of the RILIS-mode ion extraction independently of the electron density. Experiments have been performed using a prototype VADLIS with an adjustable extractor plate voltage for the generation of gallium ion beams at the off-line separator as well as magnesium, molybdenum and mercury ion beams at ISOLDE. A factor >2 increase of the VADLIS efficiency in RILIS-mode has been achieved. ispartof: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS vol:431 pages:59-66 status: published

Details

Language :
English
ISSN :
0168583X
Volume :
431
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Accession number :
edsair.doi.dedup.....d243000ee6a2caadfe8664de8b66bbb4
Full Text :
https://doi.org/10.1016/j.nimb.2018.06.006