- Purpose To compare diagnostic yield and complication rates of magnetic resonance (MR)-guided versus computed tomography (CT)- and ultrasound (US)-guided liver biopsies. Materials and Methods MR-, CT-, and US-guided liver biopsies performed between 9/96 and 9/98 were compared. Sixty patients (21 men and 39 women, mean age 60 years) underwent MR-guided biopsy of liver lesions. Thirty patients (16 men and 14 women, mean age 59 years) underwent CT-guided biopsy. Eighteen patients (seven men and 11 women, mean age 50 years) underwent US-guided biopsy. MR procedures were performed in an open-configuration 0.5-T Signa SP MR unit. Lesion localization used standard Tl and T2 sequences, whereas biopsies were performed with multiplanar spoiled gradient recalled echo and fast gradient recalled echo sequences. A coaxial system with an MR-compatible 18-gauge stabilizing needle and a 21-gauge aspiration needle was used to obtain all samples. In CT and US procedures, a 19-gauge stabilizing needle and a 21-gauge aspiration or a 20-gauge core biopsy needle were used. A cytotechnologist was present to determine the adequacy of samples. Results MR had a diagnostic yield of 61%. CT and US had diagnostic yields of 67% and 61%, respectively. No serious complications were reported for MR and US procedures. Two CT biopsies resulted in postprocedural hemorrhage. One patient required surgical exploration and died. Conclusions MR-guided biopsy of liver lesions with use of a 0.5-T open-configuration magnet is safe and accurate when compared with CT and US. No statistical difference was observed between the diagnostic yield of biopsies performed with MR, CT, and US guidance. MR enabled biopsy of a number of lesions in the hepatic dome and lesions with low contrast, which would normally be difficult to sample safely with use of CT or US.
- Subjects :
- Male
medicine.medical_specialty
Lesion
Diagnosis, Differential
Biopsy
medicine
Humans
Radiology, Nuclear Medicine and imaging
Diagnostic Errors
Retrospective Studies
Ultrasonography
Observer Variation
medicine.diagnostic_test
business.industry
Ultrasound
Biopsy, Needle
Liver Neoplasms
Reproducibility of Results
Magnetic resonance imaging
Retrospective cohort study
Middle Aged
Magnetic Resonance Imaging
Liver
Liver biopsy
Female
Radiology
Tomography
medicine.symptom
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Complication
Tomography, X-Ray Computed
Subjects
Details
- ISSN :
- 10510443
- Volume :
- 10
- Issue :
- 10
- Database :
- OpenAIRE
- Journal :
- Journal of vascular and interventional radiology : JVIR
- Accession number :
- edsair.doi.dedup.....d26d66abf4953890417d48b8e5275d90