Back to Search Start Over

Adherence to diagnostic and therapeutic practice guidelines for suspected cardiac implantable electronic device infections

Authors :
Christine Selton-Suty
Guillaume De Ciancio
Nicolas Sadoul
Marie-Line Erpelding
Yves Juillière
Hugues Blangy
François Goehringer
Nelly Agrinier
Olivier Huttin
Laura Filippetti
Source :
Archives of Cardiovascular Diseases. 114:634-646
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

Summary Background Despite guidelines describing the optimal diagnostic and therapeutic procedures for patients with suspected cardiac implantable electronic device (CIED) infections, their management is often challenging. Aims To describe our diagnostic and therapeutic practices for suspected CIED infection, and to compare them with European Heart Rhythm Association (EHRA) guidelines. Methods Patients hospitalized in the tertiary care Nancy University Hospital for suspected CIED infection from 2014 to 2019 were included retrospectively. We applied the EHRA classification of CIED infection, and compared diagnostic and therapeutic management with the EHRA guidelines. Results Among 184 patients (mean age 72.3 ± 12.4 years), 137 had a proven infection of the lead (by transthoracic echocardiography/transoesophageal echocardiography, 18F-fluorodesoxyglucose positron emission tomography/computed tomography or positive culture of the lead) or an isolated pocket infection without proof of lead infection, and 47 had no proof of CIED infection. According to the EHRA classification, CIED infection was considered as definite in 145 patients and possible in 31 and was excluded in eight patients. Regarding recommended diagnostic procedures, blood cultures were performed in 90.8%, transthoracic echocardiography in 97.8%, transoesophageal echocardiography in 85.9%, 18F-fluorodesoxyglucose positron emission tomography/computed tomography in 50.5% and imaging for embolisms in 78.3% of the patients. Compared with therapeutic recommendations for the 145 cases of definite CIED infection, device removal was performed in 96 patients (66.2%) and antibiotic therapy was prescribed in 130 (89.7%), with a duration equal to or longer than that recommended in 105 (72.4%) of the patients. Conclusion This study underlines the difficulties in following theoretical guidelines in daily practice, where both technical and human considerations interfere with their strict appliance.

Details

ISSN :
18752136
Volume :
114
Database :
OpenAIRE
Journal :
Archives of Cardiovascular Diseases
Accession number :
edsair.doi.dedup.....d34b4da322bfe96ddabdcd7d0d712374