Simultaneous Estimation of Bias and Resolution in PET Images with a Long-Lived 'Pocket' Phantom System
- Source :
- Tomography : a journal for imaging research, Tomography; Volume 4; Issue 1; Pages: 33-41, Tomography, Volume 4, Issue 1, Pages 33-41
- Publication Year :
- 2018
- Publisher :
- MDPI AG, 2018.
-
Abstract
- A challenge in multicenter trials that use quantitative positron emission tomography (PET) imaging is the often unknown variability in PET image values, typically measured as standardized uptake values, introduced by intersite differences in global and resolution-dependent biases. We present a method for the simultaneous monitoring of scanner calibration and reconstructed image resolution on a per-scan basis using a PET/computed tomography (CT) “pocket” phantom. We use simulation and phantom studies to optimize the design and construction of the PET/CT pocket phantom (120 × 30 × 30 mm). We then evaluate the performance of the PET/CT pocket phantom and accompanying software used alongside an anthropomorphic phantom when known variations in global bias (±20%, ±40%) and resolution (3-, 6-, and 12-mm postreconstruction filters) are introduced. The resulting prototype PET/CT pocket phantom design uses 3 long-lived sources (15-mm diameter) containing germanium-68 and a CT contrast agent in an epoxy matrix. Activity concentrations varied from 30 to 190 kBq/mL. The pocket phantom software can accurately estimate global bias and can detect changes in resolution in measured phantom images. The pocket phantom is small enough to be scanned with patients and can potentially be used on a per-scan basis for quality assurance for clinical trials and quantitative PET imaging in general. Further studies are being performed to evaluate its performance under variations in clinical conditions that occur in practice.
- Subjects :
- clinical trials
Scanner
Materials science
medicine.diagnostic_test
quantitative positron emission tomography imaging
calibration
standardized uptake value
Resolution (electron density)
Standardized uptake value
Pet imaging
equipment and supplies
Article
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Positron emission tomography
Calibration
medicine
Radiology, Nuclear Medicine and imaging
Anthropomorphic phantom
030217 neurology & neurosurgery
Biomedical engineering
Subjects
Details
- ISSN :
- 2379139X
- Volume :
- 4
- Database :
- OpenAIRE
- Journal :
- Tomography
- Accession number :
- edsair.doi.dedup.....d4bdbf6c264eec176f51b69a488d63cd
- Full Text :
- https://doi.org/10.18383/j.tom.2018.00004