Back to Search Start Over

LOPES-3D, an antenna array for full signal detection of air-shower radio emission

Authors :
D. Kang
P. Doll
Heino Falcke
Béatrice Fuchs
Jörg R. Hörandel
A. Horneffer
F. Di Pierro
C. Morello
J.C. Arteaga
A. Chiavassa
M. Wommer
J. Rautenberg
A. Weindl
Jan Kuijpers
Peter L. Biermann
Kai Daumiller
L. Bähren
O. Krömer
K. Bekk
C. Rühle
J. Oehlschläger
J. Blümer
Claus Grupen
P.G. Isar
V. de Souza
H. Bozdog
M. Finger
M. E. Bertaina
G.C. Trinchero
Markus Roth
H. Rebel
P. Łuczak
K. Link
N. Palmieri
A. Haungs
M. Melissas
J. Zabierowski
H. J. Mathes
H. Schieler
M. Ludwig
Alexandra Saftoiu
Karl-Heinz Kampert
G. Toma
F.G. Schröder
D. Huber
A. Schmidt
D. Fuhrmann
T. Pierog
E. Cantoni
Ralph Engel
W. D. Apel
Peter Buchholz
J. A. Zensus
I.M. Brancus
H. Gemmeke
Tim Huege
J. Wochele
Octavian Sima
D. Heck
Source :
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 696, 100-109, ResearcherID, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 696, 0, pp. 100-109
Publication Year :
2013

Abstract

To better understand the radio signal emitted by extensive air-showers and to further develop the radio detection technique of high-energy cosmic rays, the LOPES experiment was reconfigured to LOPES-3D. LOPES-3D is able to measure all three vectorial components of the electric field of radio emission from cosmic ray air showers. The additional measurement of the vertical component ought to increase the reconstruction accuracy of primary cosmic ray parameters like direction and energy, provides an improved sensitivity to inclined showers, and will help to validate simulation of the emission mechanisms in the atmosphere. LOPES-3D will evaluate the feasibility of vectorial measurements for large scale applications. In order to measure all three electric field components directly, a tailor-made antenna type (tripoles) was deployed. The change of the antenna type necessitated new pre-amplifiers and an overall recalibration. The reconfiguration and the recalibration procedure are presented and the operationality of LOPES-3D is demonstrated.

Details

Language :
English
ISSN :
01689002
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 696, 100-109, ResearcherID, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 696, 0, pp. 100-109
Accession number :
edsair.doi.dedup.....d512e0391147d8039d89549000de97ec