Is the use of hemostatic matrix (Floseal) and alkylene oxide copolymer (Ostene) safe in spinal laminectomies? Peridural fibrosis assessment
- Source :
- Acta Orthopaedica et Traumatologica Turcica, Acta Orthopaedica et Traumatologica Turcica, Vol 51, Iss 2, Pp 165-168 (2017)
- Publication Year :
- 2017
- Publisher :
- Turkish Association of Orthopaedics and Traumatology, 2017.
-
Abstract
- Objective: Failed Back Syndrome (FBS) is unacceptable relief of pain or recurrence of symptoms in patients after spinal surgery, such as laminectomy. One possible cause of FBS is peridural fibrosis (PF). PF is the overproduction of scar tissue adjacent to the dura mater. Bleeding can cause PF after laminectomy. Ostene is an alkylene oxide copolymer material used to stop bleeding from bony surfaces. Floseal is a gelatin thrombin matrix sealant used to assist fibrin formation and to promote coagulation. Methods: Total of 32 female Sprague–Dawley rats were evenly allotted to 4 experimental groups: laminectomy only, laminectomy + Ostene (Baxter International, Inc., Deerfield, IL, USA), laminectomy + Floseal (Baxter International, Inc., Deerfield, IL, USA), and laminectomy + Adcon-L (aap Implantate AG, Berlin, Germany). After performing total laminectomy, agents were placed over dura mater. Spinal column of test subjects was harvested 6 weeks after laminectomy. Histopathological examination of samples was based on Masson's trichrome and hematoxylin and eosin staining. PF observed in the groups was graded using system previously described by He et al. Statistically significant p value was defined as p < 0.005. Results: Present study revealed that Adcon-L, Ostene, and Floseal groups had reduced PF compared with laminectomy only group (p = 0.001). Comparison of Ostene and Floseal groups with Adcon-L group yielded no significant difference. Conclusion: Reoperation as result of FBS has greater risk and often has poor outcome; surgeons must take precautions to avoid FBS, such as careful selection of appropriate patient and operation technique. Ostene and Floseal may be applied and left in the operation field safely during laminectomy to reduce occurrence of PF after procedure.<br />NA
- Subjects :
- Failed back syndrome
Peridural fibrosis
Spinal surgery
Hemostatic matrix
Alkylene oxide copolymer
Dura mater
medicine.medical_treatment
030204 cardiovascular system & hematology
Matrix (biology)
Rats, Sprague-Dawley
0302 clinical medicine
Postoperative Complications
lcsh:Orthopedic surgery
Orthopedics and Sports Medicine
Lumbar Vertebrae
biology
Laminectomy
General Medicine
Gelatin Sponge, Absorbable
medicine.anatomical_structure
Coagulation
Anesthesia
Female
Spinal Diseases
medicine.drug
Research Article
medicine.medical_specialty
Poloxamer
Fibrin
03 medical and health sciences
Thrombin
medicine
Animals
Humans
business.industry
Medicine
Neurosurgery
Sealant
medicine.disease
Fibrosis
Surgery
Rats
lcsh:RD701-811
Disease Models, Animal
biology.protein
Dura Mater
business
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- ISSN :
- 25891294 and 1017995X
- Volume :
- 51
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Acta Orthopaedica et Traumatologica Turcica
- Accession number :
- edsair.doi.dedup.....d780ab108b43fd7f264e70657821be7c