Back to Search
Start Over
Acetabular defect reconstruction in revision hip arthroplasty with a modular revision system and biological defect augmentation
- Source :
- International Orthopaedics. 39:623-630
- Publication Year :
- 2014
- Publisher :
- Springer Science and Business Media LLC, 2014.
-
Abstract
- Revision of failed total hip arthroplasty with severe acetabular bone loss represents a rare but challenging problem. Anatomic reconstruction with biological defect augmentation as solid bone transplants or cancellous bone restores bone stock while providing good component stability. The objective of this study was to present short- to mid-term results of revision total hip arthroplasty with a modular ring system in a consecutive series of patients with severe acetabular bone loss. We retrospectively reviewed 39 consecutive patients (39 hips) with severe acetabular bone loss (Paprosky type 3 A and 3 B) reconstructed with revision total hip arthroplasty using the cementless modular ring system MRS-Titan®. The MRS-Titan® consists of independent ring systems that are adapted modularly to the defect situation. Combined with acetabular defect reconstruction by using cancellous bone in impaction grafting technique, the MRS-Titan® system offers a cement-free revision system that enables defect-adapted customization to individual anatomic matters, bridging of the acetabular bone defect and reconstruction of the centre of rotation. Initial stability of the implant was obtained by screw fixation. Harris hip score and sequential radiographs were used to evaluate clinical and radiographic results. At an average follow up of 31 months (range 12–69 months) 33 of 39 (84.6 %) of the implants were considered radiographically stable without signs of acetabular migration of more than 2 mm in the horizontal or vertical direction, implant rotation or screw breakage. Complications included six implant failures (15 %). We recorded one aseptic loosening of the MRS prosthesis after 20 months. Five patients (12.8 %) had to undergo revision surgery because of periprosthetic joint infection. Two patients had a dislocation postoperatively. The mean Harris hip score improved from 27 ± 14 points preoperatively to 76 ± 15 points at the time of last follow up. By achieving stable implant fixation and providing potential for biological fixation, treatment of severe acetabular bone loss in revision total hip arthroplasty with the modular ring system MRS-Titan provides a durable solution with good clinical and radiographic results and allows us to accomplish major goals of reconstruction.
- Subjects :
- Adult
Male
Reoperation
musculoskeletal diseases
medicine.medical_specialty
Arthroplasty, Replacement, Hip
medicine.medical_treatment
Bone Screws
Periprosthetic
Prosthesis Design
Prosthesis
Postoperative Complications
medicine
Humans
Orthopedics and Sports Medicine
Aged
Retrospective Studies
Fixation (histology)
Aged, 80 and over
business.industry
Bone Cements
Acetabulum
Middle Aged
Survival Analysis
Arthroplasty
Surgery
Treatment Outcome
medicine.anatomical_structure
Harris Hip Score
Orthopedic surgery
Female
Hip Prosthesis
Implant
business
Cancellous bone
Follow-Up Studies
Subjects
Details
- ISSN :
- 14325195 and 03412695
- Volume :
- 39
- Database :
- OpenAIRE
- Journal :
- International Orthopaedics
- Accession number :
- edsair.doi.dedup.....d7d703ed8e5c554415f2b16a616734cd
- Full Text :
- https://doi.org/10.1007/s00264-014-2533-5