Back to Search
Start Over
Automatic liver detection and standardised uptake value evaluation in whole-body Positron Emission Tomography/Computed Tomography scans
- Publication Year :
- 2018
- Publisher :
- Elsevier, 2018.
-
Abstract
- Background and objective: Standardised Uptake Value (SUV), in clinical research and practice, is a marker of tumour avidity in Positron Emission Tomography/Computed Tomography (PET/CT). Since many technical, physical and physiological factors affect the SUV absolute measurement, the liver uptake is often used as reference value both in quantitative and semi-quantitative evaluation. The purpose of this investigation was to automatically detect the liver position in whole-body PET/CT scans and extract its average SUV value. Methods: We developed an algorithm, called LIver DEtection Algorithm (LIDEA), that analyses PET/CT scans, and under the assumption that the liver is a large homogeneous volume near the centre of mass of the patient, finds its position and automatically places a region of interest (ROI) in the liver, which is used to calculate the average SUV. The algorithm was validated on a population of 630 PET/CT scans coming from more than 60 different scanners. The SUV was also calculated by manually placing a large ROI in the liver. Results: LIDEA identified the liver with a 97.3% sensitivity with PET/CT images only and reached a 98.9% correct detection rate when using the co-registered CT scan to avoid liver misidentification in the right lung. The average liver SUV obtained with LIDEA was successfully validated against its manual assessment, with no systematic difference (0.11 ± 0.36 SUV units) and a R 2 = 0.89 correlation coefficient. Conclusions: LIDEA proved to be a reliable tool to automatically identify and extract the average SUV of the liver in oncological whole-body PET/CT scans.
- Subjects :
- Male
Quality Control
Systematic difference
Population
Health Informatics
Multimodal Imaging
030218 nuclear medicine & medical imaging
Cohort Studies
03 medical and health sciences
0302 clinical medicine
Imaging, Three-Dimensional
Absolute measurement
Region of interest
Fluorodeoxyglucose F18
Reference Values
Positron Emission Tomography Computed Tomography
Medicine
Humans
Whole Body Imaging
education
Positron Emission Tomography-Computed Tomography
education.field_of_study
Electronic Data Processing
medicine.diagnostic_test
business.industry
Liver Neoplasms
Reproducibility of Results
Reference Standards
Computer Science Applications
SUV
Liver
Homogeneous
Positron emission tomography
030220 oncology & carcinogenesis
Positron Emission Tomography, SUV, Liver, Quality Control
Female
Radiopharmaceuticals
Whole body
business
Nuclear medicine
Software
Algorithms
Positron Emission Tomography
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....d98c430c1baf2a1a2cacbff02aa9f8e6