Back to Search Start Over

An LDV based method to quantify the error of PC-MRI derived Wall Shear Stress measurement

Authors :
Jean-Marc Rousset
Félicien Bonnefoy
J.M. Serfaty
Saïd Moussaoui
Perrine Paul-Gilloteaux
Sébastien Levilly
David Le Touzé
Jérôme Idier
Marco Castagna
unité de recherche de l'institut du thorax UMR1087 UMR6291 (ITX)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Université de Nantes - UFR de Médecine et des Techniques Médicales (UFR MEDECINE)
Université de Nantes (UN)-Université de Nantes (UN)
Laboratoire des Sciences du Numérique de Nantes (LS2N)
Université de Nantes - UFR des Sciences et des Techniques (UN UFR ST)
Université de Nantes (UN)-Université de Nantes (UN)-École Centrale de Nantes (ECN)-Centre National de la Recherche Scientifique (CNRS)-IMT Atlantique Bretagne-Pays de la Loire (IMT Atlantique)
Institut Mines-Télécom [Paris] (IMT)-Institut Mines-Télécom [Paris] (IMT)
Structure fédérative de recherche François Bonamy (SFR François Bonamy)
Université de Nantes (UN)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Institut de Recherche en Santé de l'Université de Nantes (IRS-UN)
Laboratoire de recherche en Hydrodynamique, Énergétique et Environnement Atmosphérique (LHEEA)
École Centrale de Nantes (ECN)-Centre National de la Recherche Scientifique (CNRS)
Source :
Scientific Reports, Scientific Reports, Nature Publishing Group, 2021, 11 (1), pp.4112. ⟨10.1038/s41598-021-83633-y⟩, Scientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
Publication Year :
2021
Publisher :
Nature Publishing Group UK, 2021.

Abstract

Wall Shear Stress (WSS) has been demonstrated to be a biomarker of the development of atherosclerosis. In vivo assessment of WSS is still challenging, but 4D Flow MRI represents a promising tool to provide 3D velocity data from which WSS can be calculated. In this study, a system based on Laser Doppler Velocimetry (LDV) was developed to validate new improvements of 4D Flow MRI acquisitions and derived WSS computing. A hydraulic circuit was manufactured to allow both 4D Flow MRI and LDV velocity measurements. WSS profiles were calculated with one 2D and one 3D method. Results indicated an excellent agreement between MRI and LDV velocity data, and thus the set-up enabled the evaluation of the improved performances of 3D with respect to the 2D-WSS computation method. To provide a concrete example of the efficacy of this method, the influence of the spatial resolution of MRI data on derived 3D-WSS profiles was investigated. This investigation showed that, with acquisition times compatible with standard clinical conditions, a refined MRI resolution does not improve WSS assessment, if the impact of noise is unreduced. This study represents a reliable basis to validate with LDV WSS calculation methods based on 4D Flow MRI.