Back to Search
Start Over
Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
- Source :
- Physica Medica. 45:146-155
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- Estimate organ and effective doses from computed tomography scans of pediatric oncologic patients using patient-specific information.With IRB approval patient-specific scan parameters and patient size obtained from DICOM images and vendor-provided dose monitoring application were obtained for a cross-sectional study of 1250 pediatric patients from 0 through 20 y-olds who underwent head, chest, abdomen-pelvis, or chest-abdomen-pelvis CT scans. Patients were categorized by age. Organ doses and effective doses were estimated using VirtualDoseā¢ CT based on patient-specific information, tube current modulation (TCM), and age-specific realistic phantoms. CTDIvol, DLP, and dose results were compared with those reported in the literature.CTDIvol and DLP varied widely as patient size varied. The 75th percentiles of CTDIvol and DLP were no greater than in the literature with the exception of head scans of 16-20 y-olds and of abdomen-pelvis scans of larger patients. Eye lens dose from a head scan was up to 69 mGy. Mean organ doses agreed with other studies at maximal difference of 38% for chest and 41% for abdomen-pelvis scans. Mean effective dose was generally higher for older patients. The highest effective doses were estimated for the 16-20 y-olds as: head 3.3 mSv, chest 4.1 mSv, abdomen-pelvis 10.0 mSv, chest-abdomen-pelvis 14.0 mSv.Patient-specific organ and effective doses have been estimated for pediatric oncologic patients from1 through 20 y-olds. The effect of TCM was successfully accounted for in the estimates. Output parameters varied with patient size. CTDIvol and DLP results are useful for future protocol optimization.
- Subjects :
- Male
Adolescent
Biophysics
General Physics and Astronomy
Computed tomography
Radiation Dosage
Effective dose (radiation)
Article
030218 nuclear medicine & medical imaging
Young Adult
03 medical and health sciences
0302 clinical medicine
Older patients
Neoplasms
Tube current modulation
medicine
Pediatric oncology
Body Size
Humans
Radiology, Nuclear Medicine and imaging
Child
Eye lens
Retrospective Studies
medicine.diagnostic_test
business.industry
Infant, Newborn
Infant
General Medicine
Patient specific
Dose monitoring
Cross-Sectional Studies
Child, Preschool
030220 oncology & carcinogenesis
Female
Tomography, X-Ray Computed
Nuclear medicine
business
Subjects
Details
- ISSN :
- 11201797
- Volume :
- 45
- Database :
- OpenAIRE
- Journal :
- Physica Medica
- Accession number :
- edsair.doi.dedup.....db2e3c8dedd2005b0f843524ffac55b3
- Full Text :
- https://doi.org/10.1016/j.ejmp.2017.12.013