Abstract

PurposeMulti-b-value diffusion-weighted MRI techniques can simultaneously measure the parenchymal diffusivity, microvascular perfusion, and a third, intermediate diffusion component. This component is related to the interstitial fluid in the brain parenchyma. However, simultaneously estimating three diffusion components from multi-b-value data is difficult and has strong dependence on SNR and chosen b-values. As the number of acquired b-values is limited due to scanning time, it is important to know which b-values are most effective to be included. Therefore, this study evaluates an optimized b-value sampling for interstitial fluid estimation. MethodThe optimized b-value sampling scheme is determined using a genetic algorithm. Subsequently, the performance of this optimized sampling is assessed by comparing it with a linear, logarithmic, and previously proposed sampling scheme, in terms of the RMS error (RMSE) for the intermediate component estimation. The in vivo performance of the optimized sampling is assessed using 7T data with 101 equally spaced b-values ranging from 0 to 1000 s/mm(2). In this case, the RMSE was determined by comparing the fit that includes all b-values. ResultsThe optimized b-value sampling for estimating the intermediate component was reported to be [0, 30, 90, 210, 280, 350, 580, 620, 660, 680, 720, 760, 980, 990, 1000] s/mm(2). For computer simulations, the optimized sampling had a lower RMSE, compared with the other samplings for varying levels of SNR. For the in vivo data, the voxel-wise RMSE of the optimized sampling was lower compared with other sampling schemes. ConclusionThe genetic algorithm-optimized b-value scheme improves the quantification of the diffusion component related to interstitial fluid in terms of a lower RMSE.

Details

Language :
English
ISSN :
07403194
Volume :
90
Issue :
1
Database :
OpenAIRE
Journal :
Magnetic Resonance in Medicine
Accession number :
edsair.doi.dedup.....dbf8276e81876511e23ec7b9537c59b2
Full Text :
https://doi.org/10.1002/mrm.29612