Back to Search
Start Over
Coronary Artery Stent Evaluation by Combining Iterative Reconstruction and High-resolution Kernel at Coronary CT Angiography
- Source :
- Academic Radiology. 19:1324-1331
- Publication Year :
- 2012
- Publisher :
- Elsevier BV, 2012.
-
Abstract
- To evaluate stent lumen visualization by combining high-resolution cardiac kernel and the iterative reconstruction (iDose) on an anthropomorphic moving heart phantom and in patients at coronary computed tomography (CT) angiography.We used the moving heart phantom and a 64 detector-row CT, retrospectively gated helical scanning, and image reconstruction. The heart rate was set at nonpulsating condition of 0 beats/min, 50 beats/min, and 80 beats/min. The 120-kV images were reconstructed in synchronization with electrocardiogram data using filtered back projection (FBP) or iDose algorithm and standard kernel/filter (CB) or high-resolution kernel/filter (CD). We measured image noise, the kurtosis, and stent lumen diameter in the phantom study. We also assessed the visual inspections by two radiologists.With cardiac motion at 50 and 80 beats/min, the difference of kurtosis improved with CD relative to CB (P.05). iDose algorithm with level 7 provided lowest noise, with no statistically significance in difference of the kurtosis relative to level 4 (P.05). Without cardiac motion at 0 beats/min, the stent lumen diameter measurements with CD kernel were better relative to CB kernel (P.05). In addition, no significant difference was found in stent lumen diameter between iDose level 4 and level 7 (P.05).The use of iDose and a sharp kernel allowed improved stent visualization at a lower radiation dose.
- Subjects :
- medicine.medical_specialty
genetic structures
medicine.medical_treatment
Iterative reconstruction
Coronary Angiography
Sensitivity and Specificity
Imaging phantom
chemistry.chemical_compound
Image noise
medicine
Humans
Idose
Radiology, Nuclear Medicine and imaging
medicine.diagnostic_test
Phantoms, Imaging
business.industry
Reproducibility of Results
Stent
equipment and supplies
Coronary Vessels
Radiographic Image Enhancement
Treatment Outcome
chemistry
Kernel (image processing)
Angiography
Radiographic Image Interpretation, Computer-Assisted
Stents
Radiology
Tomography
Tomography, X-Ray Computed
Nuclear medicine
business
Algorithms
Subjects
Details
- ISSN :
- 10766332
- Volume :
- 19
- Database :
- OpenAIRE
- Journal :
- Academic Radiology
- Accession number :
- edsair.doi.dedup.....dc1663f8a5665e14848509326f8e7338
- Full Text :
- https://doi.org/10.1016/j.acra.2012.06.013