Back to Search Start Over

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

Authors :
Vicki E. Noble
Joshua Caplin
Aftab Mohammad Azad
Michael A. Fifer
Andrew S. Liteplo
Aranya Bagchi
Irene W. Y. Ma
Christina Wilson
Source :
Critical Ultrasound Journal, Vol 9, Iss 1, Pp 1-8 (2017), Critical Ultrasound Journal
Publication Year :
2017
Publisher :
SpringerOpen, 2017.

Abstract

Background Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. Results Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. Conclusions Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time. Electronic supplementary material The online version of this article (doi:10.1186/s13089-017-0065-0) contains supplementary material, which is available to authorized users.

Details

Language :
English
ISSN :
20367902 and 20363176
Volume :
9
Issue :
1
Database :
OpenAIRE
Journal :
Critical Ultrasound Journal
Accession number :
edsair.doi.dedup.....de53f11f5692a44258cc0600c61197e4
Full Text :
https://doi.org/10.1186/s13089-017-0065-0