Abstract
- Hepatic encephalopathy caused by a large portosystemic shunt (PSS) can be treated by endovascular embolization of the shunt. The PSS diameter can be >20 mm; it occasionally poses technical difficulties. Here, a 72-year-old woman with liver cirrhosis, hyperammonemia, and large spleno-renal shunt underwent shunt embolization using an Amplatzer vascular plug 2 (AVP2) and metallic coils. The preloading coil in plug method (p-CIP), which facilitated embolization inside the AVP2 without cannulation from outside, was employed to overcome technical difficulties. We propose the use of p-CIP with an AVP2 as a tool for treatment of hepatic encephalopathy with PSS.
- Subjects :
- medicine.medical_specialty
Cirrhosis
medicine.medical_treatment
Preloading coil-in-plug method (p-CIP)
R895-920
Case Report
law.invention
Embolization
Medical physics. Medical radiology. Nuclear medicine
law
medicine
Radiology, Nuclear Medicine and imaging
Spark plug
Hepatic encephalopathy
business.industry
Hyperammonemia
Portosystemic shunt
medicine.disease
Shunt (medical)
Surgery
Electromagnetic coil
AVP
business
Subjects
Details
- Language :
- English
- ISSN :
- 19300433
- Volume :
- 16
- Issue :
- 10
- Database :
- OpenAIRE
- Journal :
- Radiology Case Reports
- Accession number :
- edsair.doi.dedup.....df18b08fd1a748d318c71fa17a14dcc3