Back to Search Start Over

A simple diagnostic model for ruling out pneumoconiosis among construction workers

Authors :
Suarthana, E.
Moons, K.G.M.
Heederik, D.J.J.
Meijer, E.
Risk Assessment of Toxic and Immunomodulatory Agents
Dep IRAS
Source :
Occupational and Environmental Medicine, 64, 595. BMJ Publishing Group Ltd
Publication Year :
2007
Publisher :
BMJ, 2007.

Abstract

Background: Construction workers exposed to silica-containing dust are at risk of developing silicosis even at low exposure levels. Health surveillance among these workers is commonly advised but the exact diagnostic work-up is not specified and therefore may result in unnecessary chest x ray investigations. Aim: To develop a simple diagnostic model to estimate the probability of an individual worker having pneumoconiosis from questionnaire and spirometry results, in order to accurately rule out workers without pneumoconiosis. Methods: The study was performed using cross-sectional data of 1291 Dutch natural stone and construction workers with potentially high quartz dust exposure. A multivariable logistic regression model was developed using chest x ray with ILO profusion category ⩾1/1 as the reference standard. The model’s calibration was evaluated with the Hosmer–Lemeshow test; the discriminative ability was determined by calculating the area under the receiver operating characteristic curve (ROC area). Internal validity of the final model was assessed by a bootstrapping procedure. For clinical application, the diagnostic model was transformed into an easy-to-use score chart. Results: Age 40 years or older, current smoker, high-exposure job, working 15 years or longer in the construction industry, “feeling unhealthy” and FEV 1 were independent predictors in the diagnostic model. The model showed good calibration (a non-significant Hosmer–Lemeshow test) and discriminative ability (ROC area 0.81, 95% CI 0.74 to 0.85). Internal validity was reasonable; the optimism corrected ROC area was 0.76. By using a cut-off point with a high negative predictive value the occupational physician can efficiently detect a large proportion of workers with a low probability of having pneumoconiosis and exclude them from unnecessary x ray investigations. Conclusions: This diagnostic model is an efficient and effective instrument to rule out pneumoconiosis among construction workers. Its use in health surveillance among these workers can reduce the number of redundant x ray investigations.

Details

ISSN :
13510711
Volume :
64
Database :
OpenAIRE
Journal :
Occupational and Environmental Medicine
Accession number :
edsair.doi.dedup.....df39deb198ece00973fd0386c22cdfef
Full Text :
https://doi.org/10.1136/oem.2006.027904