Back to Search
Start Over
Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography
- Source :
- Saudi Journal of Ophthalmology. 26:19-24
- Publication Year :
- 2012
- Publisher :
- Medknow, 2012.
-
Abstract
- Purpose To use optical coherence tomography (OCT) to measure corneal power and calculate intraocular lens (IOL) power in cataract surgeries after myopic and hyperopic laser vision correction (LVC). Methods Patients with previous LVC were enrolled in this prospective study at two centers (Doheny Eye Institute, Los Angeles, CA, USA and Cullen Eye Institute, Houston, TX, USA). Corneal power was measured with a Fourier-domain OCT system. The intravisit repeatability of OCT corneal power measurement was evaluated by the pooled standard deviation of repeat scans. Axial length, anterior chamber depth, and automated keratometry were measured with the IOLMaster. An OCT-based IOL formula was developed. The mean absolute error (MAE) of refractive prediction for OCT-based IOL formula was calculated. The results were compared with the MAE for Haigis-L formula. Results A total of 31 eyes of 24 subjects who had uncomplicated cataract surgery with monofocal IOL implantation were enrolled in the two sites. Twenty-two eyes of 16 subjects had previous myopic LVC that ranged from −12.46D to −0.88D. Nine eyes of 8 subjects had previous hyperopic LVC that ranged from 0.66D to 5.52D. The intravisit repeatability of OCT corneal power measurement was 0.24D. For the myopic LVC group, the OCT formula had a MAE of 0.57D compared to an MAE of 0.73D for the Haigis-L formula ( p =0.19). For the hyperopic LVC group, the MAE for OCT and Haigis-L formula was 0.26D and 0.54D, respectively ( p >0.05). Conclusions Corneal power can be precisely measured with OCT. The predictive accuracy of OCT-based IOL power calculation is equal to current standards for post-LVC eyes.
- Subjects :
- medicine.medical_specialty
genetic structures
PRK
medicine.medical_treatment
Intraocular lens
law.invention
Optical coherence tomography
law
Ophthalmology
medicine
Cataract Update
medicine.diagnostic_test
Keratometer
business.industry
LASIK
Repeatability
Cataract surgery
Laser
eye diseases
Optometry
Intraocular lens power calculation
sense organs
business
Lasik
Subjects
Details
- ISSN :
- 13194534
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Saudi Journal of Ophthalmology
- Accession number :
- edsair.doi.dedup.....e466dd02f52d3b169a2bbc65a51c208d
- Full Text :
- https://doi.org/10.1016/j.sjopt.2011.10.004