Back to Search
Start Over
Assessment and comparison of bacterial load levels determined by quantitative amplifications in blood culture-positive and negative neonatal sepsis
- Source :
- Revista do Instituto de Medicina Tropical de São Paulo; Vol. 60 (2018); e61, Revista do Instituto de Medicina Tropical de São Paulo; v. 60 (2018); e61, Revista do Instituto de Medicina Tropical de São Paulo, Instituto de Medicina Tropical (IMT), instacron:IMT, Revista do Instituto de Medicina Tropical de São Paulo, Volume: 60, Article number: e61, Published: 25 OCT 2018, Revista do Instituto de Medicina Tropical de São Paulo, Vol 60, Iss 0 (2018), Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual), Universidade de São Paulo (USP), instacron:USP
- Publication Year :
- 2018
- Publisher :
- Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo, 2018.
-
Abstract
- Bacterial sepsis remains a major cause of mortality and blood cultures are the gold standard of laboratory diagnosis even though they lack sensitivity in neonates. Culturenegative sepsis, also known as clinical sepsis, has long been considered a diagnosis in neonatal intensive care units because, as well as culture-positive infants, culture-negative neonates have worse prognosis in comparison with non-infected ones. Quantitative amplifications are used to detect bacterial infections in neonates but results are considered only in a qualitative way (positive or negative). The aim of the present study was to determine and compare bacterial load levels in blood culture-positive and culture-negative neonatal sepsis. Seventy neonates with clinical and laboratory evidence of infection admitted at three neonatal intensive care units were classified as blood culture-positive or culture-negative. Blood samples obtained at the same time of blood cultures had bacterial load levels assessed through a 16S rDNA qPCR. Blood cultures were positive in 29 cases (41.4%) and qPCR in 64 (91.4%). In the 29 culture-positive cases, 100% were also positive by qPCR, while in the 41 culture-negative cases, 35 (85.4%) were positive by qPCR. Bacterial load levels were in general < 50 CFU/mL, but were significantly higher in culture-positive cases (Mann-Whitney, p = 0.013), although clinical and laboratory findings were similar, excepting for deaths. In conclusion, the present study has shown that blood culture-negative neonates have lower bacteria load levels in their bloodstream when compared to blood culture-positive infants.
- Subjects :
- medicine.medical_specialty
lcsh:Arctic medicine. Tropical medicine
lcsh:RC955-962
Real-Time Polymerase Chain Reaction
Blood culture
Sepsis
Cohort Studies
03 medical and health sciences
0302 clinical medicine
030225 pediatrics
Internal medicine
Intensive care
Intensive Care Units, Neonatal
16S rDNA
medicine
Humans
Culture-negative neonatal sepsis
030212 general & internal medicine
Prospective Studies
Prospective cohort study
Neonatal blood stream infection
Gram-Positive Bacterial Infections
Neonatal sepsis
medicine.diagnostic_test
business.industry
Infant, Newborn
Gold standard (test)
Real Time PCR
medicine.disease
Prognosis
Bacterial Load
Real-time polymerase chain reaction
Original Article
Neonatal Sepsis
business
Gram-Negative Bacterial Infections
REAÇÃO EM CADEIA POR POLIMERASE
Cohort study
Subjects
Details
- Language :
- English
- ISSN :
- 16789946 and 00364665
- Database :
- OpenAIRE
- Journal :
- Revista do Instituto de Medicina Tropical de São Paulo; Vol. 60 (2018); e61, Revista do Instituto de Medicina Tropical de São Paulo; v. 60 (2018); e61, Revista do Instituto de Medicina Tropical de São Paulo, Instituto de Medicina Tropical (IMT), instacron:IMT, Revista do Instituto de Medicina Tropical de São Paulo, Volume: 60, Article number: e61, Published: 25 OCT 2018, Revista do Instituto de Medicina Tropical de São Paulo, Vol 60, Iss 0 (2018), Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual), Universidade de São Paulo (USP), instacron:USP
- Accession number :
- edsair.doi.dedup.....e6a0f7960111df3abbf7c06a63a8bffd