Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

Authors :
A. Mrozik
S. Della Monaca
Laura Panzeri
Maria Christina Quattrini
Eftychia Kouroukla
Paola Fattibene
Christopher Ian Burbidge
Clemens Woda
Paweł Bilski
Marco Martini
B. Marczewska
Ivan Veronese
B. Bulanek
R.W. Smith
Anna Galli
Sergey Sholom
Emanuela Bortolin
Therése Geber-Bergstrand
Daniela Ekendahl
V. Cauwels
Stephen W.S. McKeever
C. Bassinet
Bassinet, C
Woda, C
Bortolin, E
Della Monaca, S
Fattibene, P
Quattrini, M
Bulanek, B
Ekendahl, D
Burbidge, C
Cauwels, V
Kouroukla, E
Geber Bergstrand, T
Mrozik, A
Marczewska, B
Bilski, B
Sholom, S
Mckeever, S
Smith, R
Veronese, I
Galli, A
Panzeri, L
Martini, M
Institut de Radioprotection et de Sûreté Nucléaire (IRSN)
Helmholtz-Zentrum München (HZM)
Istituto Superiore di Sanita` (ISS)
Durham University
Lund University [Lund]
Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, 31-342 Krakow, Poland
Oklahoma State University [Stillwater]
Università degli Studi di Milano [Milano] (UNIMI)
Istituto Nazionale di Fisica Nucleare, Sezione di Milano (INFN)
Istituto Nazionale di Fisica Nucleare (INFN)
Istituto Nazionale di Fisica Nucleare, Sezione di Lecce (INFN, Sezione di Lecce)
241536Seventh Framework Programme, FP7
Source :
Radiation Measurements, Radiation Measurements, Elsevier, 2014, 71, pp.475-479. ⟨10.1016/j.radmeas.2014.03.016⟩
Publication Year :
2014
Publisher :
Elsevier BV, 2014.

Abstract

International audience; In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an interlaboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. © 2014 Elsevier Ltd. All rights reserved.