Back to Search Start Over

Sensitivity of subject-specific models to errors in musculo-skeletal geometry

Authors :
Vincenzo Carbone
Hubertus F.J.M. Koopman
van der M.M. Krogt
Nico Verdonschot
Faculty of Engineering Technology
Rehabilitation medicine
MOVE Research Institute
Source :
Journal of biomechanics, 45(14), 2476-2480. Elsevier, Journal of Biomechanics, 45, 14, pp. 2476-80, Journal of Biomechanics, 45(14), 2476-2480. Elsevier Limited, Journal of Biomechanics, 45, 2476-80, Carbone, V, van der Krogt, M M, Koopman, H F J M & Verdonschot, N 2012, ' Sensitivity of subject-specific models to errors in musculo-skeletal geometry ', Journal of Biomechanics, vol. 45, no. 14, pp. 2476-2480 . https://doi.org/10.1016/j.jbiomech.2012.06.026
Publication Year :
2012

Abstract

Item does not contain fulltext Subject-specific musculo-skeletal models of the lower extremity are an important tool for investigating various biomechanical problems, for instance the results of surgery such as joint replacements and tendon transfers. The aim of this study was to assess the potential effects of errors in musculo-skeletal geometry on subject-specific model results. We performed an extensive sensitivity analysis to quantify the effect of the perturbation of origin, insertion and via points of each of the 56 musculo-tendon parts contained in the model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by only the perturbed musculo-tendon parts and by all the remaining musculo-tendon parts, respectively, during a simulated gait cycle. Results indicated that, for each musculo-tendon part, only two points show a significant sensitivity: its origin, or pseudo-origin, point and its insertion, or pseudo-insertion, point. The most sensitive points belong to those musculo-tendon parts that act as prime movers in the walking movement (insertion point of the Achilles Tendon: LSI=15.56%, OSI=7.17%; origin points of the Rectus Femoris: LSI=13.89%, OSI=2.44%) and as hip stabilizers (insertion points of the Gluteus Medius Anterior: LSI=17.92%, OSI=2.79%; insertion point of the Gluteus Minimus: LSI=21.71%, OSI=2.41%). The proposed priority list provides quantitative information to improve the predictive accuracy of subject-specific musculo-skeletal models.

Details

ISSN :
00219290
Volume :
45
Database :
OpenAIRE
Journal :
Journal of Biomechanics
Accession number :
edsair.doi.dedup.....e84fad3678e3421be36f9d383f7d787f