Clinical Experience of Automated SBRT Paraspinal and Other Metastatic Tumor Planning With Constrained Hierarchical Optimization
- Source :
- Advances in Radiation Oncology, Advances in Radiation Oncology, Vol 5, Iss 5, Pp 1042-1050 (2020)
- Publication Year :
- 2019
-
Abstract
- Purpose We report on the clinical performance of a fully automated approach to treatment planning based on a Pareto optimal, constrained hierarchical optimization algorithm, named Expedited Constrained Hierarchical Optimization (ECHO). Methods and materials From April 2017 to October 2018, ECHO produced 640 treated plans for 523 patients who underwent stereotactic body radiation therapy (RT) for paraspinal and other metastatic tumors. A total of 182 plans were for 24 Gy in a single fraction, 387 plans were for 27 Gy in 3 fractions, and the remainder were for other prescriptions or fractionations. Of the plans, 84.5% were for paraspinal tumors, with 69, 302, and 170 in the cervical, thoracic, and lumbosacral spine, respectively. For each case, after contouring, a template plan using 9 intensity modulated RT fields based on disease site and tumor location was sent to ECHO through an application program interface plug-in from the treatment planning system. ECHO returned a plan that satisfied all critical structure hard constraints with optimal target volume coverage and the lowest achievable normal tissue doses. Upon ECHO completion, the planner received an e-mail indicating the plan was ready for review. The plan was accepted if all clinical criteria were met. Otherwise, a limited number of parameters could be adjusted for another ECHO run. Results The median planning target volume size was 84.3 cm3 (range, 6.9-633.2). The median time to produce 1 ECHO plan was 63.5 minutes (range, 11-340 minutes) and was largely dependent on the field sizes. Of the cases, 79.7% required 1 run to produce a clinically accepted plan, 13.3% required 1 additional run with minimal parameter adjustments, and 7.0% required ≥2 additional runs with significant parameter modifications. All plans met or bettered the institutional clinical criteria. Conclusions We successfully implemented automated stereotactic body RT paraspinal and other metastatic tumors planning. ECHO produced high-quality plans, improved planning efficiency and robustness, and enabled expedited treatment planning at our clinic.
- Subjects :
- lcsh:Medical physics. Medical radiology. Nuclear medicine
Contouring
medicine.medical_specialty
Critical structure
Stereotactic body radiation therapy
business.industry
lcsh:R895-920
Echo (computing)
Planning target volume
lcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
Metastatic tumor
lcsh:RC254-282
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Oncology
Intensity Modulated RT
030220 oncology & carcinogenesis
medicine
Radiology, Nuclear Medicine and imaging
Scientific Article
Radiology
Radiation treatment planning
business
Subjects
Details
- ISSN :
- 24521094
- Volume :
- 5
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Advances in radiation oncology
- Accession number :
- edsair.doi.dedup.....e94f60554aed1499ceb17081371ee559