Back to Search Start Over

Avaliação da liberação de cálcio e alteração de pH de forradores cavitários fotoativados para capeamento pulpar

Authors :
Milton Carlos Kuga
Kamila de Figueiredo Pereira
Andrea Abi Rached Dantas
Rosymere Freitas de Sousa Cruvinel
Universidade Estadual Paulista (Unesp)
Universidade de Rio Verde
Source :
Revista de Odontologia da UNESP, Vol 47, Iss 4, Pp 205-209 (2018), SciELO, Repositório Institucional da UNESP, Universidade Estadual Paulista (UNESP), instacron:UNESP, Revista de Odontologia da UNESP, Volume: 47, Issue: 4, Pages: 205-209, Published: 13 AUG 2018, Revista de Odontologia da UNESP v.47 n.4 2018, Revista de Odontologia da UNESP, Revista de Odontologia da UNESP, Issue: ahead, Published: 13 AUG 2018
Publication Year :
2018
Publisher :
Universidade Estadual Paulista, 2018.

Abstract

Made available in DSpace on 2018-11-12T17:27:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-08-01. Added 1 bitstream(s) on 2018-11-12T17:35:15Z : No. of bitstreams: 1 S1807-25772018000400205.pdf: 135962 bytes, checksum: d6c2aef31e5047bcf0209c84ab524378 (MD5) ResumoIntroduçãoForradores cavitários à base de hidróxido de cálcio apresentam baixa resistência e alta solubilidade. Para resolver este problema, foi desenvolvido forradores à base de hidróxido de cálcio fotoativáveis contendo resina para melhorar suas propridades.ObjetivoA proposta deste estudo foi avaliar a alteração de pH e liberação de cálcio de forradores fotoativáveis.Material e métodoForam preparadas amostras (n=10) com Ultra-Blend® plus, Biocal ® (cimentos fotoativáveis) e Hydro C® (controle). As amostras foram armazenadas com 10 mL de água destilada e mantidas em estufa à 37 °C. Depois de 24 horas, 7 e 14 dias, foram avaliados os níveis de liberação de cálcio e a alteração de pH. Os dados foram analisados estatisticamente pelo teste ANOVA, seguido do pós teste Tukey (α = 0.05).ResultadoOs resultados de pH mostraram Hydro C > Ultra-Blend plus > Biocal. Biocal apresentou a pior liberação de cálcio.ConclusãoMateriais fotoativados apresentam menor liberação de cálcio e alteração nos valores de pH. AbstractIntroductionCavity liners based calcium hydroxide present low strength and high solubility that is consider a disadvantage. In order to enhance these properties it was developed a light-cured cavity liner based calcium hydroxide containing resin.ObjectiveThe purpose of this study was to evaluate the pH and calcium release of light-cured cavity liners.Material and methodThere were prepared specimens (n=10) with the Ultra-Blend ® plus, Biocal® (light cured cements) and Hydro C® (control). The samples were stored in 10 mL of distilled water and maintained at 37 °C. After 24 hours, 7, and 14 days, there were analyzed pH and the release of calcium levels. The data were statistically analyzed by ANOVA and Tukey test (α = 0.05).ResultThe results of pH showed Hydro C > Ultra-Blend plus > Biocal. Biocal presented worst calcium release.ConclusionLight-cured materials present lower calcium release and alteration in pH values. Universidade Estadual Paulista Faculdade de Odontologia de Araraquara Universidade de Rio Verde Universidade Estadual Paulista Faculdade de Odontologia de Araraquara

Details

Language :
English
ISSN :
18072577
Volume :
47
Issue :
4
Database :
OpenAIRE
Journal :
Revista de Odontologia da UNESP
Accession number :
edsair.doi.dedup.....ea16e2cdc8a4add16ec9d74b82505858