Back to Search Start Over

Accurate Diagnosis of Cortical and Infratentorial Lesions in Multiple Sclerosis Using Accelerated Fluid and White Matter Suppression Imaging

Authors :
Martin, Anna
Emorine, Thibaut
Megdiche, Imen
Creange, Alain
Kober, Tobias
Massire, Aurelien
Bapst, Blanche
Source :
Investigative Radiology. 58:337-345
Publication Year :
2022
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2022.

Abstract

Objectives: The precise location of multiple sclerosis (MS) cortical lesions can be very challenging at 3 T, yet distinguishing them from subcortical lesions is essential for the diagnosis and prognosis of the disease. Compressed sensing-accelerated fluid and white matter suppression imaging (CS-FLAWS) is a new magnetic resonance imaging sequence derived from magnetization-prepared 2 rapid acquisition gradient echo with promising features for the detection and classification of MS lesions. The objective of this study was to compare the diagnostic performances of CS-FLAWS(evaluated imaging) and phase sensitive inversion recovery (PSIR; reference imaging) for classification of cortical lesions (primary objective) and infratentorial lesions (secondary objective) in MS, in combination with 3-dimensional (3D) double inversion recovery (DIR).<br />Materials and Methods: Prospective 3 T scans (MS first diagnosis or follow-up) acquired between March and August 2021 were retrospectively analyzed. All underwent 3D CS-FLAWS, axial 2D PSIR, and 3D DIR. Double-blinded reading sessions exclusively in axial plane and final consensual reading were performed to assess the number of cortical and infratentorial lesions. Wilcoxon test was used to compare the 2 imaging datasets (FLAWS + DIR and PSIR + DIR), and intraobserver and interobserver agreement was assessed using the intraclass correlation coefficient.<br />Results: Forty-two patients were analyzed (38 with relapsing-remitting MS, 29 women, 42.7 +/- 12.6 years old). Compressed sensing-accelerated FLAWS allowed the identification of 263 cortical lesions versus 251 with PSIR (P = 0.74) and 123 infratentorial lesions versus 109 with PSIR (P = 0.63), corresponding to a nonsignificant difference between the 2 sequences. Compressed sensing-accelerated FLAWS exhibited fewer false-negative findings than PSIR either for cortical lesions (1 vs 13; P < 0.01) or infratentorial lesions (1 vs 15; P < 0.01). No false-positive findings were found with any of the 2 sequences. Diagnostic confidence was high for each contrast.<br />Conclusion: Three-dimensional CS-FLAWS is as accurate as 2D PSIR imaging for classification of cortical and infratentorial MS lesions, with fewer false-negative findings, opening the way to a reliable full brain MS exploration in a clinically acceptable duration (5 minutes 15 seconds).

Details

ISSN :
15360210 and 00209996
Volume :
58
Database :
OpenAIRE
Journal :
Investigative Radiology
Accession number :
edsair.doi.dedup.....ec6e6d180cc96e2f9019a0a24d0b6304
Full Text :
https://doi.org/10.1097/rli.0000000000000939