Back to Search
Start Over
Surface studies of coarse-grained and nanostructured titanium implants
- Source :
- Journal of Nanoscience and Nanotechnology
- Publication Year :
- 2013
-
Abstract
- The results of XPS measurements of nanostructured Ti (ns-Ti) prepared with a help of severe plastic deformation (SPD) have been presented. We have measured XPS spectra of core levels (Ti 2p, O 1s, C 1s, F 1s and valence bands before and after treatment of ns-Ti-implants in HF. The obtained data have been compared with XPS measurements of untreated and acid treated coarsegrained Ti (cg-Ti). According to these measurements the surface composition has not practically been changed by reduction of grains size of Ti-implants. It has been found that the surface of both types of implants is covered with thick TiO 2 layer. The acid treatment reduces the surface contamination of ns-Ti and cg-Ti by hydrocarbons and induces better passivation and formation of more thick TiO2 layer. It has been shown that severe plastic deformation not only improves mechanical properties but also preserves corrosion stability of Ti-implants. Copyright © 2012 American Scientific Publishers.
- Subjects :
- Materials science
Passivation
Macromolecular Substances
Surface Properties
COARSE-GRAINED TITANIUM
Biomedical Engineering
Molecular Conformation
Bioengineering
Nanostructured titanium
ELECTRONIC STRUCTURE OF SURFACE
Spectral line
Corrosion
X-ray photoelectron spectroscopy
Materials Testing
XPS
General Materials Science
NANOSTRUCTURED TITANIUM
Composite material
Particle Size
Titanium
Valence (chemistry)
General Chemistry
Equipment Design
Prostheses and Implants
Condensed Matter Physics
Nanostructures
Equipment Failure Analysis
Acid treatment
Severe plastic deformation
Subjects
Details
- ISSN :
- 15334880
- Volume :
- 12
- Issue :
- 11
- Database :
- OpenAIRE
- Journal :
- Journal of nanoscience and nanotechnology
- Accession number :
- edsair.doi.dedup.....ecd441d8234f12d51c324161ef77bd8e