Back to Search
Start Over
Surgical aortic valve replacement with new-generation bioprostheses: Sutureless versus rapid-deployment
- Publication Year :
- 2019
- Publisher :
- MOSBY-ELSEVIER, 2019.
-
Abstract
- The aim of this retrospective multicenter study was to compare early clinical and hemodynamic outcomes of Perceval-S sutureless (Livanova, London, United Kingdom) and Intuity rapid-deployment (Edwards Lifesciences, Irvine, Calif) bioprostheses.Data from patients who underwent isolated or combined aortic valve replacement with Perceval-S and with Intuity bioprostheses at 18 cardiac surgical institutions were analyzed. Propensity matching was performed to identify similar patient cohorts.We included 911 patients from March 2011 until May 2017. Perceval-S and Intuity valves were implanted in 349 (38.3%) and in 562 (61.7%) patients, respectively. Propensity score identified 117 matched pairs. In the matched cohort, device success was 99.1% and 100% in Perceval-S and Intuity group, respectively (P = 1.000). Thirty-day Valve Academic Research Consortium mortality occurred in 2 (1.7%) and 4 (3.4%) patients in the Perceval-S and in Intuity group, respectively (P = .6834). The rate of postoperative new permanent pacemaker implantation was 6% (7 patients) and 6.8% (8 patients) in the Perceval-S and in Intuity group, respectively (P = .7896). Perceval-S valve implantation requires significantly shorter aortic crossclamp and cardiopulmonary bypass times than Intuity valve implantation (aortic crossclamp time for isolated, 52 ± 14 minutes vs 62 ± 24 minutes; P .0001). Peak transaortic gradients were 22.4 ± 8.1 mm Hg and 19.6 ± 6.7 mm Hg (P = .0144), whereas mean gradients were 11.8 ± 4.7 mm Hg and 10.5 ± 3.9 mm Hg (P = .0388) in the Perceval-S and Intuity groups, respectively.Sutureless Perceval-S and rapid-deployment Intuity bioprostheses provide good and similar early clinical and hemodynamic outcomes. Perceval-S valve implantation requires shorter crossclamp and cardiopulmonary bypass times, whereas Intuity valve implantation provides lower transaortic peak and mean gradients.
- Subjects :
- Pulmonary and Respiratory Medicine
Male
medicine.medical_specialty
aortic valve
rapid deployment aortic bioprosthesis
replacement
sutureless aortic bioprosthesis
Hemodynamics
030204 cardiovascular system & hematology
law.invention
03 medical and health sciences
0302 clinical medicine
Matched cohort
Aortic valve replacement
law
Cardiopulmonary bypass
80 and over
Humans
Medicine
Settore MED/23 - CHIRURGIA CARDIACA
Aged
Retrospective Studies
Aged, 80 and over
Heart Valve Prosthesis Implantation
Bioprosthesis
Aortic Valve
Aortic Valve Stenosis
Female
Sutureless Surgical Procedures
Heart Valve Prosthesis
business.industry
medicine.disease
Surgery
Settore MED/23
030228 respiratory system
Multicenter study
Propensity score matching
Permanent pacemaker
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....eddf645d5a16765466541878c22bae3a