Back to Search Start Over

Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring

Authors :
Dae Suk Yang
Seong Ho Park
Sang Beom Ma
Kwang Won Lee
Seung Hak Oh
Source :
Knee Surgery & Related Research, Vol 33, Iss 1, Pp 1-8 (2021), Knee Surgery & Related Research
Publication Year :
2021
Publisher :
Springer Science and Business Media LLC, 2021.

Abstract

BackgroundFor treating displaced patella fractures, tension band wiring is the most widely used technique. However, implant removal surgery is often necessary to alleviate discomfort caused by fixation materials. On the contrary, fixation using nonabsorbable suture materials is anticipated to result in comparable outcomes without need for further implant removal surgery. However, there is a lack of clinical studies comparing the two fixation techniques (wire and nonabsorbable suture materials) for acute patella fractures.MethodsFrom 2014 to 2018, we retrospectively reviewed 60 patients who underwent open reduction with internal fixation for acute patella fracture. Thirty patients (group 1) who received surgery using tension band wiring and 30 patients (group 2) who received surgery using nonabsorbable suture materials were enrolled. The average follow-up period was more than 1 year after operation. Operation time, postoperative bone union time, range of motion (ROM) of the knee joint, postoperative clinical results, and complications were compared between the two groups.ResultOperation time, clinical bone union, and radiologic bone union were not statistically different between groups 1 and 2. At 3 months postoperatively, flexion was 120.3 ± 9.4° in group 1 and 110.5 ± 7.7° in group 2, showing statistically significant difference (p = 0.037). At 6 and 12 months postoperatively, the ROM was similar in both groups. Hospital for special surgery score at 3 months postoperatively was 78.4 ± 8.2 in group 1 and 83.7 ± 8.7 in group 2, showing statistically significant differences (p = 0.032). However, at 6 and 12 months postoperatively, there were no statistical differences. Lysholm score at 3 months postoperatively was 73.5 ± 8.1 in group 1 and 80.4 ± 8.2 in group 2, showing statistically significant difference (p = 0.016), but at 6 and 12 months postoperatively, there were no statistical differences.ConclusionFixation using multiple nonabsorbable suture materials can be an alternative surgical method in managing patella fractures, along with tension band wiring.

Details

ISSN :
22342451
Volume :
33
Database :
OpenAIRE
Journal :
Knee Surgery & Related Research
Accession number :
edsair.doi.dedup.....ef2a30eba17ba9405cce2f13084ae215
Full Text :
https://doi.org/10.1186/s43019-021-00116-0