Back to Search
Start Over
Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry
- Source :
- Dvir, D, Webb, J, Brecker, S, Bleiziffer, S, Hildick-Smith, D, Colombo, A, Descoutures, F, Hengstenberg, C, Moat, N E, Bekeredjian, R, Napodano, M, Testa, L, Lefevre, T, Guetta, V, Nissen, H, Hernández, J-M, Roy, D, Teles, R C, Segev, A, Dumonteil, N, Fiorina, C, Gotzmann, M, Tchetche, D, Abdel-Wahab, M, De Marco, F, Baumbach, A, Laborde, J-C & Kornowski, R 2012, ' Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves : Results From the Global Valve-in-Valve Registry ', Circulation, vol. 126, no. 19, pp. 2335-44 . https://doi.org/10.1161/CIRCULATIONAHA.112.104505
- Publication Year :
- 2012
-
Abstract
- Background— Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. Methods and Results— The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. Conclusions— The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
- Subjects :
- Male
Cardiac Catheterization
medicine.medical_treatment
Diseases::Cardiovascular Diseases::Heart Diseases::Heart Valve Diseases::Aortic Valve Stenosis [Medical Subject Headings]
Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Heart Valve Prosthesis [Medical Subject Headings]
Global Health
New york heart association
Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans [Medical Subject Headings]
Prótesis Valvulares Cardíacas
Valve replacement
80 and over
Medicine
Registries
Aged, 80 and over
Heart Valve Prosthesis Implantation
Incidence
Estenosis de la Válvula Aórtica
Analytical, Diagnostic and Therapeutic Techniques and Equipment::Equipment and Supplies::Prostheses and Implants::Bioprosthesis [Medical Subject Headings]
Treatment Outcome
Aortic Valve
Heart Valve Prosthesis
Diseases::Cardiovascular Diseases::Vascular Diseases::Arterial Occlusive Diseases::Arteriosclerosis::Coronary Artery Disease [Medical Subject Headings]
Cardiology
Diseases::Cardiovascular Diseases::Heart Diseases::Heart Valve Diseases::Aortic Valve Insufficiency [Medical Subject Headings]
Equipment Failure
Female
Insuficiencia de la Válvula Aórtica
Cardiology and Cardiovascular Medicine
Reoperation
valve-in-valve
medicine.medical_specialty
Transcatheter aortic
Resultado del Tratamiento
Aortic Valve Insufficiency
Regurgitation (circulation)
Enfermedad de la Arteria Coronaria
Physiology (medical)
Internal medicine
Humans
bioprosthesis
transcatheter aortic valve implantation
Aged
Aortic Valve Stenosis
Bioprosthesis
Follow-Up Studies
Retrospective Studies
Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Vascular Surgical Procedures::Endovascular Procedures::Catheterization, Central Venous [Medical Subject Headings]
Analytical, Diagnostic and Therapeutic Techniques and Equipment::Diagnosis::Prognosis::Treatment Outcome [Medical Subject Headings]
Transcatheter aortic valve implantation
business.industry
Cateterismo Venoso Central
Retrospective cohort study
Surgical valves
medicine.disease
Valve in valve
Surgery
Stenosis
Analytical, Diagnostic and Therapeutic Techniques and Equipment::Surgical Procedures, Operative::Cardiovascular Surgical Procedures::Cardiac Surgical Procedures [Medical Subject Headings]
Valve-in-valve
business
Implantación de Prótesis de Válvulas Cardíacas
Subjects
Details
- ISSN :
- 15244539
- Volume :
- 126
- Issue :
- 19
- Database :
- OpenAIRE
- Journal :
- Circulation
- Accession number :
- edsair.doi.dedup.....f237584432e050f52024026a7d480627
- Full Text :
- https://doi.org/10.1161/CIRCULATIONAHA.112.104505