Back to Search
Start Over
A portable setup for the voltammetric determination of total mercury in fish with solid and nanostructured gold electrodes
- Source :
- Molecules, Volume 24, Issue 10, Molecules, Vol 24, Iss 10, p 1910 (2019)
- Publication Year :
- 2019
-
Abstract
- A simple procedure for field fish sample pretreatment was developed. This treatment in combination with square wave anodic stripping voltammetry (SW-ASV) with solid gold electrodes (SGE) and gold nanoparticle-modified glassy carbon electrodes (AuNPs-GCE) was applied for the determination of total mercury content. A certified reference material (CRM, Tuna Fish BCR 463), ten freeze-dried samples of canned tuna and two fresh fish samples were analysed both with a bench-top voltammetric analyser after microwave digestion and with a portable potentiostat after mild eating using a small commercial food warmer. The results obtained by the two SW-ASV approaches and by a Direct Mercury Analyser (DMA), the official method for mercury determination, were in very good agreement. In particular, (i) the results obtained with in field procedure are consistent with those obtained with the conventional microwave digestion<br />(ii) the presence of gold nanoparticles on the active electrode surface permits an improvement of the analytical performance in comparison to the SGE: the Limit of Quantification (LOQ) for mercury in fish-matrix was 0.1 &mu<br />g L&minus<br />1 (Hg cell concentration), corresponding to 0.06 mg kg&minus<br />1 wet fish, which is a performance comparable to that of DMA. The pretreatment proposed in this study is very easy and applicable to fresh fish<br />in combination with a portable potentiostat, it proved to be an interesting procedure for on-site mercury determination.
- Subjects :
- Materials science
Pharmaceutical Science
chemistry.chemical_element
Metal Nanoparticles
02 engineering and technology
Glassy carbon
Anodic stripping voltammetry
01 natural sciences
Article
Analytical Chemistry
lcsh:QD241-441
lcsh:Organic chemistry
Limit of Detection
Food Preservation
Drug Discovery
Animals
Microwave digestion
Physical and Theoretical Chemistry
Electrodes
Direct mercury analyser
Gold electrodes
Mercury
On-site analysis
Detection limit
Chromatography
Mercury in fish
Tuna
Drug Discovery3003 Pharmaceutical Science
010401 analytical chemistry
Organic Chemistry
021001 nanoscience & nanotechnology
Potentiostat
0104 chemical sciences
Mercury (element)
Certified reference materials
chemistry
Chemistry (miscellaneous)
Molecular Medicine
3003
Gold
0210 nano-technology
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Molecules, Volume 24, Issue 10, Molecules, Vol 24, Iss 10, p 1910 (2019)
- Accession number :
- edsair.doi.dedup.....f391f3263c4bbc26c209ca62feba3b21