Back to Search
Start Over
Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study
- Source :
- BMC Oral Health, BMC Oral Health, Vol 20, Iss 1, Pp 1-11 (2020)
- Publication Year :
- 2020
-
Abstract
- Background One of the most recent innovations in bone augmentation surgery is represented by computer-aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study was to evaluate the effectiveness/reliability of this technique in a consecutive series of cases. Methods Ten patients in need of bone augmentation before implant therapy were treated using CAD/CAM customized titanium meshes. A digital workflow was adopted to design virtual meshes on 3D bone models. Then, Direct Metal Laser Sintering (DMLS) technology was used to produce the titanium meshes, and vertical ridge augmentation was performed according to an established surgical protocol. Surgical complications, healing complications, vertical bone gain (VBG), planned bone volume (PBV), lacking bone volume (LBV), regenerated bone volume (RBV), average regeneration rate (RR) and implant success rate were evaluated. Results All augmented sites were successfully restored with definitive implant-supported fixed partial dentures. Measurements showed an average VBG of 4.5 ± 1.8 mm at surgical re-entry. Surgical and healing complications occurred in 30% and 10% of cases, respectively. Mean values of PBV, LBV, and RBV were 984, 92, and 892 mm3, respectively. The average RR achieved was 89%. All 26 implants were successfully in function after 1 year of follow-up. Conclusions The results of this study suggest that the bone augmentation by means of DMLS custom-made titanium meshes can be considered a reliable and effective technique in restoring vertical bone defects.
- Subjects :
- Custom-made
Dental implant
chemistry.chemical_element
Pilot Projects
CAD
computer.software_genre
Computer-aided-design/computer-aided-manufacturing
03 medical and health sciences
0302 clinical medicine
Humans
Medicine
Computer Aided Design
Polygon mesh
030212 general & internal medicine
Alveolar ridge augmentation
General Dentistry
Dental Implants
Titanium
Computers
business.industry
Reproducibility of Results
030206 dentistry
Alveolar Ridge Augmentation
lcsh:RK1-715
Titanium meshes
Direct metal laser sintering
chemistry
lcsh:Dentistry
Computer-aided manufacturing
Computer-Aided Design
Implant
business
computer
Research Article
Biomedical engineering
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- BMC Oral Health, BMC Oral Health, Vol 20, Iss 1, Pp 1-11 (2020)
- Accession number :
- edsair.doi.dedup.....f3f1d715a38d309eb87e042f77337f79