Back to Search
Start Over
Reliability of the Star Excursion Balance Test and Two New Similar Protocols to Measure Trunk Postural Control
- Source :
- PM&R. 10:1344-1352
- Publication Year :
- 2018
- Publisher :
- Wiley, 2018.
-
Abstract
- Background Although the Star Excursion Balance test (SEBT) has shown a good intrasession reliability, the intersession reliability of this test has not been deeply studied. Furthermore, there is an evident high influence of the lower limbs in the performance of the SEBT, so even if it has been used to measure core stability, it is possibly not the most suitable measurement. Objective (1) To assess the absolute and relative between-session reliability of the SEBT and 2 novel variations of this test to assess trunk postural control while sitting, ie, the Star Excursion Sitting Test (SEST) and the Star Excursion Timing Test (SETT); and (2) to analyze the relationships between these 3 test scores. Design Correlational and reliability test–retest study. Setting Controlled laboratory environment. Participants Twenty-seven physically active men (age: 24.54 ± 3.05 years). Method Relative and absolute reliability of the SEBT, SEST, and SETT were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), respectively. A Pearson correlation analysis was carried out between the variables of the 3 tests. Main Outcome Measures Maximum normalized reach distances were assessed for different SEBT and SEST directions. In addition, composite indexes were calculated for SEBT, SEST, and SETT. Results The SEBT (dominant leg: ICC = 0.87 [0.73-0.94], SEM = 2.12 [1.66-2.93]; nondominant leg: ICC = 0.74 [0.50-0.87], SEM = 3.23 [2.54-4.45]), SEST (ICC = 0.85 [0.68-0.92], SEM = 1.27 [1.03-1.80]), and SETT (ICC = 0.61 [0.30-0.80], SEM = 2.31 [1.82-3.17]) composite indexes showed moderate-to-high 1-month reliability. A learning effect was detected for some SEBT and SEST directions and for SEST and SETT composite indexes. No significant correlations were found between SEBT and its 2 variations (r ≤ .366; P > .05). A significant correlation was found between the SEST and SETT composite indexes (r = .520; P > .01). Conclusions SEBT, SEST, and SETT are reliable field protocols to measure postural control. However, whereas the SEBT assesses postural control in single-leg stance, SEST and SETT provide trunk postural control measures with lower influence of the lower-limbs. Level of Evidence III
- Subjects :
- Adult
Male
medicine.medical_specialty
Intraclass correlation
Physical Therapy, Sports Therapy and Rehabilitation
Balance test
Motor Activity
Sitting
Upper Extremity
Young Adult
03 medical and health sciences
0302 clinical medicine
Physical medicine and rehabilitation
Clinical Protocols
Humans
Medicine
Postural Balance
Reliability (statistics)
Sitting Position
030222 orthopedics
business.industry
Rehabilitation
Excursion
Reproducibility of Results
Torso
Core stability
030229 sport sciences
Trunk
Standard error
Lower Extremity
Neurology
Standing Position
Female
Neurology (clinical)
business
Subjects
Details
- ISSN :
- 19341563 and 19341482
- Volume :
- 10
- Database :
- OpenAIRE
- Journal :
- PM&R
- Accession number :
- edsair.doi.dedup.....f453e9a60eccf6d1ae0ec7b780c11938
- Full Text :
- https://doi.org/10.1016/j.pmrj.2018.05.012