Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease

Authors :
Michel Versluis
Johannes T. Boersen
Erik Groot Jebbink
Peter Goverde
Cornelis H. Slump
Chao Sun
Michel M.P.J. Reijnen
Varghese Mathai
Faculty of Science and Technology
Technical Medicine
Physics of Fluids
Source :
Journal of vascular surgery, 66(1), 251-260. Elsevier
Publication Year :
2016

Abstract

Background Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. Methods Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. Results The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. Conclusions The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch. The CERAB configuration is the most unimpaired physiologic reconstruction, whereas BMK and CK stents have their typical zones of flow recirculation.

Details

ISSN :
10976809 and 07415214
Volume :
66
Issue :
1
Database :
OpenAIRE
Journal :
Journal of vascular surgery
Accession number :
edsair.doi.dedup.....f49ea88bb65e08312f802adc7af23005