Back to Search Start Over

Protection from internal faults in a special high power switching conversion system for thermonuclear fusion application

Authors :
H. Decamps
C. Finotti
Daniele Falchi
Carlo Panizza
Loris Zanotto
Elena Gaio
M. Dan
M. Perna
Daniel Gutierrez
Alessandro Premoli
Source :
2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS), 2017 IEEE 12th International Conference on Power Electronics and Drive Systems (IEEE PEDS 2017), pp. 252–258, Honolulu, Hawaii, December 12-15, 2017, info:cnr-pdr/source/autori:Zanotto Loris; Dan Mattia; Gaio Elena; Gutierrez Daniel; Decamps Hans; Perna Mauro; Falchi Daniele; Finotti Claudio; Panizza Carlo; Premoli Alessandro/congresso_nome:2017 IEEE 12th International Conference on Power Electronics and Drive Systems (IEEE PEDS 2017)/congresso_luogo:Honolulu, Hawaii/congresso_data:December 12-15, 2017/anno:2017/pagina_da:252/pagina_a:258/intervallo_pagine:252–258, 12th IEEE International Conference on Power Electronics and Drive Systems, PEDS 2017, pp. 252–258, Kalakaua AveHonolulu, Hawaii, United States, December 12-15, 2017, info:cnr-pdr/source/autori:Zanotto L.; Dan M.; Gaio E.; Gutierrez D.; Decamps H.; Perna M.; Falchi D.; Finotti C.; Panizza C.; Premoli A./congresso_nome:12th IEEE International Conference on Power Electronics and Drive Systems, PEDS 2017/congresso_luogo:Kalakaua AveHonolulu, Hawaii, United States/congresso_data:December 12-15, 2017/anno:2018/pagina_da:252/pagina_a:258/intervallo_pagine:252–258
Publication Year :
2017

Abstract

This paper compares different provisions to protect a special high power switching power supply from internal short-faults, in particular internal short-circuits. The power supply is based on a five three-phase NPC inverters, with common dc-link, rated for a total power of about 60MW and for an output voltage of 6.5kV, using IGCTs as switching components. A large, distributed, capacitor bank is connected at the dc-link side of the inverters, with huge amount of stored energy, as high as 760kJ during nominal operation. In case of internal short-circuit of one inverter leg, due for example to a failure of one IGCT, this energy is discharged into the faulty leg, potentially leading to explosion and fault propagation. Simulations have been performed in order to analyze, select and design the most suitable protection to avoid this risk.

Details

ISBN :
978-1-5090-2364-6
ISBNs :
9781509023646
Database :
OpenAIRE
Journal :
2017 IEEE 12th International Conference on Power Electronics and Drive Systems (PEDS)
Accession number :
edsair.doi.dedup.....f4ea8b6f0a2a4b2a17ed6031e9455383
Full Text :
https://doi.org/10.1109/peds.2017.8289113