Back to Search
Start Over
The Brain is Not Flat: Conformal Electrode Arrays Diminish Complications of Subdural Electrode Implantation, A Series of 117 Cases
- Source :
- World Neurosurgery. 144:e734-e742
- Publication Year :
- 2020
- Publisher :
- Elsevier BV, 2020.
-
Abstract
- Intracranial recordings are integral to evaluating patients with pharmacoresistant epilepsy whom noninvasive testing fails to localize seizure focus. Although stereo-electroencephalography is the preferred method of intracranial recordings in most centers, subdural electrode (SDE) implantation is necessary in selected cases.To identify imaging correlates that predict SDE complications (extra-axial fluid collections [EFCs]), and determine if modifications that diminish stiffness of electrode sheets reduce complications.A prospective epilepsy surgery database was used to identify adults undergoing craniotomy for SDE implantation over a 14-year period. EFCs and midline shift were measured via magnetic resonance imaging and computed tomography imaging. Correlation analyses and multivariable logistic regression explored associations between use of conformal arrays, serial order of patients, previous ipsilateral intracranial surgery, midline shift, number of SDEs, and neurologic complications.A total of 111 consecutive patients (59 female) underwent 117 craniotomies (mean, 115 electrode contacts) for SDE implantation. There were 8 surgical complications, 3 in the first 17 (17.7%). and 5 (after electrode modifications) in a subsequent 100 craniotomies (5.0%). We noted an increase in electrode numbers implanted over time (P0.001) and decreased midline shift with conformal grids (ρ = - 0.32; P0.001). A multivariable regression showed that midline shift correlated with complications (odds ratio, 2.32; 95% confidence interval, 1.12-4.78; P = 0.023).Hemorrhagic complications after SDE implantation are difficult to detect because of artifact from electrodes, but predictable by prominent midline shift (4 mm). Risks inherent to SDE implantation may be minimized using conformal grids. With symptomatic EFCs, a single electrode cable exit site allows hematoma evacuation without terminating intracranial recordings.
- Subjects :
- Adult
Male
medicine.medical_specialty
Adolescent
medicine.medical_treatment
Subdural Space
Young Adult
03 medical and health sciences
Postoperative Complications
0302 clinical medicine
Midline shift
Humans
Medicine
Epilepsy surgery
Prospective Studies
Craniotomy
medicine.diagnostic_test
business.industry
Magnetic resonance imaging
Middle Aged
Pharmacoresistant epilepsy
Magnetic Resonance Imaging
Electrodes, Implanted
Hematoma, Subdural
030220 oncology & carcinogenesis
Hemorrhagic complication
Electrode
Female
Surgery
Neurology (clinical)
Radiology
Tomography, X-Ray Computed
business
Subdural electrodes
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 18788750
- Volume :
- 144
- Database :
- OpenAIRE
- Journal :
- World Neurosurgery
- Accession number :
- edsair.doi.dedup.....f4f8def76acd8e1441d61e8e658665db