Back to Search Start Over

Investigation on the performance of a thick ceramic gas electron multiplier

Authors :
Zhimeng Hu
Andrea Muraro
Giuseppe Gorini
Oisin McCormack
Enrico Perelli Cippo
Marco Tardocchi
Zhijia Sun
Xiaojuan Zhou
Jianrong Zhou
Yuguang Xie
Yuanbo Chen
Hui Zhang
Tieshuan Fan
Gabriele Croci
Hu, Z
Muraro, A
Gorini, G
Mccormack, O
Cippo, E
Tardocchi, M
Sun, Z
Zhou, X
Zhou, J
Xie, Y
Chen, Y
Zhang, H
Fan, T
Croci, G
Source :
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 1034 (2022): 166824-1–166824-11. doi:10.1016/j.nima.2022.166824, info:cnr-pdr/source/autori:Hu Z.; Muraro A.; Gorini G.; McCormack O.; Perelli Cippo E.; Tardocchi M.; Sun Z.; Zhou X.; Zhou J.; Xie Y.; Chen Y.; Zhang H.; Fan T.; Croci G./titolo:Investigation on the performance of a thick ceramic gas electron multiplier/doi:10.1016%2Fj.nima.2022.166824/rivista:NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT/anno:2022/pagina_da:166824-1/pagina_a:166824-11/intervallo_pagine:166824-1–166824-11/volume:1034
Publication Year :
2022

Abstract

We report the performance of a THick Gas Electron Multiplier (THGEM) fabricated by drilling holes in a gold-clad ceramic substrate using the standard PCB (Printed Circuit Board) technology and etching rims. The THGEM has a total thickness of 200 ?m with a hole diameter and rim size of 200 ?m and 80 ?m, respectively. In order to carry out a performance study, a detector was assembled by putting the THGEM inside a versatile chamber and irradiating it with a 55Fe X-ray source (5.9 keV). An Ar/CO2 gas mixture was flushed inside the chamber at a pressure of about 1 atm, with volume ratios varying between 70/30 and 90/10. Pulse height spectra of the detector were recorded by a multichannel analyzer to investigate the gain and energy resolution at different drift and induction electric fields. The variations in the gain and energy resolution were also interpreted using simulations. The gain and resolution data of the THGEM were compared with those of a standard GEM which was measured using the same experimental setup.

Details

Language :
English
Database :
OpenAIRE
Journal :
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 1034 (2022): 166824-1–166824-11. doi:10.1016/j.nima.2022.166824, info:cnr-pdr/source/autori:Hu Z.; Muraro A.; Gorini G.; McCormack O.; Perelli Cippo E.; Tardocchi M.; Sun Z.; Zhou X.; Zhou J.; Xie Y.; Chen Y.; Zhang H.; Fan T.; Croci G./titolo:Investigation on the performance of a thick ceramic gas electron multiplier/doi:10.1016%2Fj.nima.2022.166824/rivista:NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT/anno:2022/pagina_da:166824-1/pagina_a:166824-11/intervallo_pagine:166824-1–166824-11/volume:1034
Accession number :
edsair.doi.dedup.....f7546a4e02e0e182727e58f0b35118cd
Full Text :
https://doi.org/10.1016/j.nima.2022.166824