Back to Search Start Over

Energy expenditure of type-specific sedentary behaviors estimated using sensewear mini armband

Authors :
Weimo Zhu
Peijie Chen
Siya Wang
Zheng Zhu
Jing Jin
Jie Zhuang
Source :
Kinesiology, Volume 50., Issue 1.
Publication Year :
2018
Publisher :
Faculty of Kinesiology, University of Zagreb, 2018.

Abstract

SenseWear Mini Armband, an accelerometer with multiple physiological sensors, could be a practical means to estimate energy expenditure (EE) of children and adolescents, but its validity reported for these age groups has not been consistent within the literature. EE of twenty-six healthy Chinese 12-year-old adolescents was measured simultaneously using both SenseWear Mini Armband (SWMA) and metabolic chamber (MC) during a 16-hour stay in a MC. SWMA systematically underestimated the adolescents’ EE during sedentary behaviors, resting metabolic rate (RMR), basal metabolic rate (BMR), and total EE, with the absolute error rate ranging from 14.85% to 28.65%. The SWMA significantly underestimated EE compared with MC in Chinese adolescents. However, the amount of error can be reduced by applying correction equation proposed in this study. Key words: sitting, physical inactivity, accelerometer, activity monitor, whole-room calorimetry

Details

ISSN :
1848638X and 13311441
Volume :
50
Database :
OpenAIRE
Journal :
Kinesiology
Accession number :
edsair.doi.dedup.....fa9c07f0545db4163a48c32225c05a45
Full Text :
https://doi.org/10.26582/k.50.1.14