Back to Search
Start Over
Wear resistance of a modified polymethyl methacrylate artificial tooth compared to five commercially available artificial tooth materials
- Source :
- The Journal of Prosthetic Dentistry. 114:286-292
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- Statement of problem Wear resistance is a limitation of artificial denture teeth. Improving the wear resistance of conventional artificial denture teeth is of value to prosthodontic patients. Purpose The purpose of this in vitro study was to evaluate the wear resistance and hardness of modified polymethyl methacrylate artificial denture teeth compared to 5 commercially available artificial tooth materials. Material and methods This study evaluated 180 artificial denture teeth (6 groups) that included 3 groups of conventional artificial teeth (MajorDent, Cosmo HXL, and Gnathostar), 2 groups of composite resin artificial teeth (Endura and SR Orthosit PE), and 1 group of modified surface artificial teeth. The flattened buccal surface of each tooth (n=15) was prepared for investigation with the Vickers hardness test and the elucidate wear test (n=15) by using a brushing machine. Each group was loaded for 18 000 cycles, at 2 N, and 150 rpm. The wear value was identified with a profilometer. The data were statistically analyzed by using 1-way ANOVA and post hoc Turkey honestly significant difference tests (α=.001). The tribologies were observed under a scanning electron microscope, and the cytotoxicities were evaluated by MTT assay. Results The Vickers hardnesses ranged from 28.48 to 39.36. The wear depths and worn surface area values ranged from 1.12 to 10.79 μm and from 6.74 to 161.95 μm 2 . The data revealed that the modified artificial denture teeth were significantly harder and exhibited significantly higher wear resistance than did the conventional artificial teeth ( P 001). The scanning electron microscopic images revealed cross sections of the conventional artificial denture teeth with intensively worn surface areas after brushing. The cytotoxicity test revealed 97.85% cell viability, which indicates the nontoxicity of the modified surface of this material. Conclusions Within the limitations of this study, the polymethyl methacrylate modified surface artificial denture teeth was not significantly different from that of the composite resin artificial denture teeth, with the exceptions that the surface was harder and more wear resistant.
- Subjects :
- Toothbrushing
Materials science
Polymethyl methacrylate
Surface Properties
Scanning electron microscope
Polyurethanes
Acrylic Resins
Dentistry
Biocompatible Materials
Tooth, Artificial
Composite Resins
Nanocomposites
Dental Restoration Wear
Dental Materials
stomatognathic system
Hardness
Buccal Surface
Materials Testing
Polymethyl Methacrylate
business.industry
Significant difference
Silanes
Silicon Dioxide
Wear resistance
stomatognathic diseases
Vickers hardness test
Microscopy, Electron, Scanning
Wear resistant
Stress, Mechanical
Oral Surgery
business
Subjects
Details
- ISSN :
- 00223913
- Volume :
- 114
- Database :
- OpenAIRE
- Journal :
- The Journal of Prosthetic Dentistry
- Accession number :
- edsair.doi.dedup.....fb998a5ce52627612e8ea724c6d08e22
- Full Text :
- https://doi.org/10.1016/j.prosdent.2015.01.013