Back to Search Start Over

Preclinical evaluation of a monoclonal antibody targeting the epidermal growth factor receptor as a radioimmunodiagnostic and radioimmunotherapeutic agent

Authors :
Michael Williams
Kayhan Garmestani
Geoffrey L. Ray
Martin W. Brechbiel
Diane E. Milenic
Kwamena E. Baidoo
Karen J. Wong
Source :
British Journal of Pharmacology. 157:1541-1548
Publication Year :
2009
Publisher :
Wiley, 2009.

Abstract

The studies described here are the first to evaluate the in vitro and in vivo properties of (111)In-CHX-A''-panitumumab for radioimmunotherapy (alpha- and beta(-)-emitters) and radioimmunoimaging (single photon emission computed tomography and positron emission tomography).Twenty-seven human carcinoma cell lines were analysed for expression of epidermal growth factor receptors by flow cytometry. Panitumumab was conjugated with CHX-A''-DTPA (diethylenetriamine-pentaacetic acid) and radiolabelled with (111)In. Immunoreactivity of the CHX-A''-DTPA-panitumumab and (111)In-CHX-A''-DTPA-panitumumab was evaluated by radioimmunoassays. Tumour targeting was determined in vivo by direct quantitation of tumour and normal tissues and by gamma-scintigraphy.For 26 of 27 human tumour cell lines, 95% of the cells expressed epidermal growth factor receptors over a range of intensity. Immunoreactivity of panitumumab was retained after modification with CHX-A''-DTPA. Radiolabelling of the immunoconjugate with (111)In was efficient with a specific activity of 19.5 +/- 8.9 mCi.mg(-1) obtained. Immunoreactivity and specificity of binding of the (111)In-panitumumab was shown with A431 cells. Tumour targeting by (111)In-panitumumab was demonstrated in athymic mice bearing A431, HT-29, LS-174T, SHAW or SKOV-3 s.c. xenografts with little uptake observed in normal tissues. The (111)In-panitumumab was also evaluated in non-tumour-bearing mice. Pharmacokinetic studies compared the plasma retention time of the (111)In-panitumumab in both non-tumour-bearing and A431 tumour-bearing mice. Tumour targeting was also visualized by gamma-scintigraphy.Panitumumab can be efficiently radiolabelled with (111)In with high labelling yields. Based on the efficiency in tumour targeting and low normal tissue uptake, panitumumab may be an effective targeting component for radioimmunodiagnostic and radioimmunotherapeutic applications.

Details

ISSN :
14765381 and 00071188
Volume :
157
Database :
OpenAIRE
Journal :
British Journal of Pharmacology
Accession number :
edsair.doi.dedup.....fd8a1612a44853e5b9ae5868d69c0a01
Full Text :
https://doi.org/10.1111/j.1476-5381.2009.00327.x