Back to Search
Start Over
Broadband and highly sensitive comb-assisted cavity ring down spectroscopy of CO near 1.57µm with sub-MHz frequency accuracy
- Source :
- Journal of Quantitative Spectroscopy and Radiative Transfer, Journal of Quantitative Spectroscopy and Radiative Transfer, Elsevier, 2015, 154, ⟨10.1016/j.jqsrt.2014.11.021⟩, Journal of Quantitative Spectroscopy & Radiative Transfer 154 (2015): 35–43. doi:10.1016/j.jqsrt.2014.11.021, info:cnr-pdr/source/autori:Mondelain, D.; Sala, T.; Kassi, S.; Romanini, D.; Marangoni, M.; Campargue, A./titolo:Broadband and highly sensitive comb-assisted cavity ring down spectroscopy of CO near 1.57 mu m with sub-MHz frequency accuracy/doi:10.1016%2Fj.jqsrt.2014.11.021/rivista:Journal of Quantitative Spectroscopy & Radiative Transfer/anno:2015/pagina_da:35/pagina_a:43/intervallo_pagine:35–43/volume:154
- Publication Year :
- 2015
- Publisher :
- HAL CCSD, 2015.
-
Abstract
- A self-referenced frequency comb has been combined with a cavity ring down (CRD) spectrometer to achieve a sub-MHz accuracy on the derived positions of the absorption lines. The frequency emitted by the distributed feedback (DFB) laser diode used in the spectrometer was obtained from the frequency of its beat note with the closest mode of the frequency comb. This delivers excellent frequency accuracy over a broad spectral region with sensitivity (noise equivalent absorption) of 1 x 10(-11) cm(-1) Hz(-1/2). This setup is used to measure the absorption spectrum of CO over a wide range corresponding to the 3-0 band (6172.5-6418.0 cm(-1)). Accurate values of line centers are measured for a total of 184 lines of four CO isotopologues, namely (CO)-C-12-O-60, (CO)-C-13-O-16, (CO)-C-12-O-18 and (CO)-C-12-O-17 present in "natural" abundances in our sample. The measurements include the first extensive study of the 3-0 band of (CO)-C-12-O-18 and (CO)-C-12-O-17, of the 4-1 hot band of (CO)-C-12-O-16 and the detection of new high-J transitions of the 3-0 band of (CO)-C-12-O-16 up to J=34. The line centers were corrected for the self-pressure shift and used to derive the upper state spectroscopic parameters. The obtained standard deviation of about 300 kHz and 500 kHz for the 3-0 band of (CO)-C-12-O-16 and of the minor isotopologues, respectively, is a good estimate of the average accuracy of the reported line centers. The resulting 3-0 line list of (CO)-C-12-O-16 provided as Supplementary material includes 69 reference line positions with a 300 kHz accuracy for the 6183-6418 cm(-1) region. (C) 2014 Elsevier Ltd. All rights reserved.
- Subjects :
- Absorption spectroscopy
02 engineering and technology
01 natural sciences
Hot band
Cavity ring-down spectroscopy
law.invention
Reference frequency
010309 optics
Frequency comb
Optics
law
0103 physical sciences
Broadband
Isotopologue
Carbon monoxide
Spectroscopy
ComputingMilieux_MISCELLANEOUS
Physics
[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]
Radiation
Spectrometer
Laser diode
business.industry
021001 nanoscience & nanotechnology
Atomic and Molecular Physics, and Optics
CO
CRDS
0210 nano-technology
business
Subjects
Details
- Language :
- English
- ISSN :
- 00224073
- Database :
- OpenAIRE
- Journal :
- Journal of Quantitative Spectroscopy and Radiative Transfer, Journal of Quantitative Spectroscopy and Radiative Transfer, Elsevier, 2015, 154, ⟨10.1016/j.jqsrt.2014.11.021⟩, Journal of Quantitative Spectroscopy & Radiative Transfer 154 (2015): 35–43. doi:10.1016/j.jqsrt.2014.11.021, info:cnr-pdr/source/autori:Mondelain, D.; Sala, T.; Kassi, S.; Romanini, D.; Marangoni, M.; Campargue, A./titolo:Broadband and highly sensitive comb-assisted cavity ring down spectroscopy of CO near 1.57 mu m with sub-MHz frequency accuracy/doi:10.1016%2Fj.jqsrt.2014.11.021/rivista:Journal of Quantitative Spectroscopy & Radiative Transfer/anno:2015/pagina_da:35/pagina_a:43/intervallo_pagine:35–43/volume:154
- Accession number :
- edsair.doi.dedup.....fdc9f0ee1883b9e315c213bc3ff8fdad
- Full Text :
- https://doi.org/10.1016/j.jqsrt.2014.11.021⟩