Back to Search Start Over

Development of a new sensor based on micro-electro-mechanical systems for objective in vivo measurement of the cutaneous temperature: application to foundations

Authors :
Philippe Humbert
Pascal Ränsch
Germaine Gazano
J M Sainthillier
Rodolphe Korichi
Sophie Mac-Mary
Ahmed Elkhyat
Eric Viviant
Christian Mahé
LVMH Recherche
LVMH Moët Hennessy Louis Vuitton
Département de dermatologie
Centre Hospitalier Régional Universitaire de Besançon (CHRU Besançon)-Hôpital Saint-Jacques-Université de Franche-Comté (UFC)
Université Bourgogne Franche-Comté [COMUE] (UBFC)-Université Bourgogne Franche-Comté [COMUE] (UBFC)
MEMSCAP SA
Interactions hôte-greffon-tumeur, ingénierie cellulaire et génique - UFC (UMR INSERM 1098) (RIGHT)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Franche-Comté (UFC)
Université Bourgogne Franche-Comté [COMUE] (UBFC)-Université Bourgogne Franche-Comté [COMUE] (UBFC)-Etablissement français du sang [Bourgogne-Franche-Comté] (EFS [Bourgogne-Franche-Comté])
Laboratoires La Licorne, SA
Saas, Philippe
Université de Franche-Comté (UFC)
Université Bourgogne Franche-Comté [COMUE] (UBFC)-Université Bourgogne Franche-Comté [COMUE] (UBFC)-Hôpital Saint-Jacques-Centre Hospitalier Régional Universitaire de Besançon (CHRU Besançon)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Etablissement français du sang [Bourgogne-Franche-Comté] (EFS [Bourgogne-Franche-Comté])-Université de Franche-Comté (UFC)
Source :
Skin Research and Technology, Skin Research and Technology, Wiley, 2006, 12 (3), pp.206-10. ⟨10.1111/j.0909-752X.2006.00156.x⟩
Publication Year :
2006

Abstract

International audience; BACKGROUND/AIMS: The purpose of this work was to develop a new sensor for objective in vivo measurement of the cutaneous temperature based on micro-electro-mechanical systems (MEMS), and to compare these performances with those of a classical thermocouple. Research on this new sensor was carried out to allow the quantification of the thermal properties of the made-up skin. METHODS: Sixteen female subjects divided into two different age groups (18-35 and >50 years old) were recruited for this study. Several zones of the face and forearms were made up at random with foundations containing or not a thermoregulator raw material. The quantity of foundation applied on the skin was standardized and measurements were carried out first before make-up, and then 10 s and 5 min after make-up. The new sensor and the thermocouple were used successively on each zone. The cutaneous temperature was expressed in degrees celsius. RESULTS/CONCLUSION: The two systems are similar in terms of repeatability and reproducibility, with some differences in sensibility. The data measured by the MEMS sensor appear lower than those measured by the thermocouple. After make-up, the MEMS sensor detects a progressive increase of the temperature in time whereas the thermocouple detects a decrease. We found the same evolution on the face but in a more attenuated way. These results tend to show that the devices do not measure the same phenomenon. The thermocouple appears more sensitive to the thermal response of the made-up surface whereas the MEMS sensor appears more sensitive to the heat transfers in the interface between the skin and make-up.

Details

ISSN :
0909752X and 16000846
Volume :
12
Issue :
3
Database :
OpenAIRE
Journal :
Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)
Accession number :
edsair.doi.dedup.....fee0ca105065e929f263c4aadacb0206