Effects of blood flow dynamics on autologous pericardial degeneration in reconstructed pulmonary arteries
- Source :
- Interactive CardioVascular and Thoracic Surgery. 26:293-300
- Publication Year :
- 2017
- Publisher :
- Oxford University Press (OUP), 2017.
-
Abstract
- OBJECTIVES To clarify the risk factors for abnormal degeneration of autologous pericardium, the mechanical stress on the endothelial tissue caused by turbulent blood flow in the pulmonary artery (PA) reconstructed with autologous pericardium and major aortopulmonary collateral arteries was assumed in pulmonary atresia and ventricular septal defect. METHODS Patient-specific PA models were created for 6 patients based on their past computed tomography images taken after unifocalization of major aortopulmonary collateral arteries. Computational fluid dynamics models were created to simulate the physiological pulsatile flow including the peripheral reflection wave, characteristic impedance and autonomous regulation system. Flow streamline, wall shear stress (WSS) and the oscillatory shear index (OSI) were calculated from the simulated result. PA degeneration was evaluated with the computed tomography images before the intracardiac repair. RESULTS Regions with physiological high WSS had fewer abnormal changes. Excessively high WSS was often detected at the anastomosis site of the reconstructed PA, and intimal thickening was found in these regions during intracardiac repair. Regions with high OSI and low WSS had dilated change within several months. In 1 patient, in particular, detached vortex flow occurred at the rectangular angle anastomosis site of the right PA in flow streamline, resulting in high OSI and low WSS with abnormal enlargement in the pericardium. CONCLUSIONS Endothelial stress caused by blood flow would affect the degeneration of autologous pericardium and major aortopulmonary collateral arteries in the reconstructed PA. High OSI and low WSS might induce enlargement or dilatation, and excessively high WSS in the anastomosis site might induce intimal thickening.
- Subjects :
- Heart Septal Defects, Ventricular
Male
Patient-Specific Modeling
Pulmonary and Respiratory Medicine
medicine.medical_specialty
Pulsatile flow
Collateral Circulation
Pulmonary Artery
030204 cardiovascular system & hematology
Anastomosis
Transplantation, Autologous
Intracardiac injection
03 medical and health sciences
0302 clinical medicine
Internal medicine
medicine.artery
Major aortopulmonary collateral artery
Humans
Medicine
Pericardium
business.industry
Anastomosis, Surgical
Hemodynamics
Infant
Blood flow
medicine.disease
medicine.anatomical_structure
030228 respiratory system
Pulmonary Atresia
Regional Blood Flow
Child, Preschool
Pulsatile Flow
Pulmonary artery
cardiovascular system
Cardiology
Female
Surgery
Stress, Mechanical
Cardiology and Cardiovascular Medicine
business
Pulmonary atresia
Subjects
Details
- ISSN :
- 15699285 and 15699293
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Interactive CardioVascular and Thoracic Surgery
- Accession number :
- edsair.doi.dedup.....ff23ed2f12a79047da69301a31d986a7
- Full Text :
- https://doi.org/10.1093/icvts/ivx293