Back to Search Start Over

Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials

Authors :
Ellingson, BM
Bendszus, M
Boxerman, J
Barboriak, D
Erickson, BJ
Smits, M
Nelson, SJ
Gerstner, E
Alexander, B
Goldmacher, G
Wick, W
Vogelbaum, M
Weller, M
Galanis, E
Kalpathy-Cramer, J
Shankar, L
Jacobs, P
Pope, WB
Yang, D
Chung, C
Knopp, MV
Cha, S
Van Den Bent, MJ
Chang, S
Al Yung, WK
Cloughesy, TF
Wen, PY
Gilbert, MR
Whitney, A
Sandak, D
Musella, A
Haynes, C
Wallace, M
Arons, DF
Kingston, A
Source :
Ellingson, BM; Bendszus, M; Boxerman, J; Barboriak, D; Erickson, BJ; Smits, M; et al.(2015). Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials. Neuro-Oncology, 17(9), 1188-1198. doi: 10.1093/neuonc/nov095. UCSF: Retrieved from: http://www.escholarship.org/uc/item/2dw3q7jq
Publication Year :
2015
Publisher :
eScholarship, University of California, 2015.

Abstract

© 2015 The Author(s). A recent joint meeting was held on January 30, 2014, with the US Food and Drug Administration (FDA), National Cancer Institute (NCI), clinical scientists, imaging experts, pharmaceutical and biotech companies, clinical trials cooperative groups, and patient advocate groups to discuss imaging endpoints for clinical trials in glioblastoma. This workshop developed a set of priorities and action items including the creation of a standardized MRI protocol for multicenter studies. The current document outlines consensus recommendations for a standardized Brain Tumor Imaging Protocol (BTIP), along with the scientific and practical justifications for these recommendations, resulting from a series of discussions between various experts involved in aspects of neuro-oncology neuroimaging for clinical trials. The minimum recommended sequences include: (i) parameter-matched precontrast and postcontrast inversion recovery-prepared, isotropic 3D T1-weighted gradient-recalled echo; (ii) axial 2D T2-weighted turbo spin-echo acquired after contrast injection and before postcontrast 3D T1-weighted images to control timing of images after contrast administration; (iii) precontrast, axial 2D T2-weighted fluid-attenuated inversion recovery; and (iv) precontrast, axial 2D, 3-directional diffusion-weighted images. Recommended ranges of sequence parameters are provided for both 1.5 T and 3 T MR systems.

Details

Language :
English
Database :
OpenAIRE
Journal :
Ellingson, BM; Bendszus, M; Boxerman, J; Barboriak, D; Erickson, BJ; Smits, M; et al.(2015). Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials. Neuro-Oncology, 17(9), 1188-1198. doi: 10.1093/neuonc/nov095. UCSF: Retrieved from: http://www.escholarship.org/uc/item/2dw3q7jq
Accession number :
edsair.od.......325..21818591e0c19b3cbcd3a4fe500b5dbe
Full Text :
https://doi.org/10.1093/neuonc/nov095.