Back to Search Start Over

A CUPID (Li2MoO4)-Mo-100 scintillating bolometer tested in the CROSS underground facility

Authors :
Armatol, A
Armengaud, E
Armstrong, W
Augier, C
III, Avignone FT
Azzolini, O
Bandac, IC
Barabash, AS
Bari, G
Barresi, A
Baudin, D
Bellini, F
Benato, G
Beretta, M
Berge, L
Bourgeois, Ch
Biassoni, M
Billard, J
Boldrini, V
Branca, A
Brofferio, C
Bucci, C
Calvo-Mozota, JM
Camilleri, J
Candela, A
Capelli, S
Cappelli, L
Cardani, L
Carniti, P
Casali, N
Cazes, A
Celi, E
Chang, C
Chapellier, M
Charrier, A
Chiesa, D
Clemenza, M
Colantoni, I
Collamati, F
Copello, S
Cremonesi, O
Creswick, RJ
Cruciani, A
D'Addabbo, A
D'Imperio, G
Dafinei, I
Danevich, FA
de Combarieu, M
De Deo, M
De Jesus, M
de Marcillac, P
Dell'Oro, S
Di Domizio, S
Dompe, V
Drobizhev, A
Dumoulin, L
Fantini, G
Faverzani, M
Ferri, E
Ferri, F
Ferroni, F
Figueroa-Feliciano, E
Formaggio, J
Franceschi, A
Fu, C
Fu, S
Fujikawa, BK
Gascon, J
Giachero, A
Gironi, L
Giuliani, A
Gorla, P
Gotti, C
Gras, P
Gros, M
Guerard, E
Gutierrez, TD
Han, K
Hansen, EV
Heeger, KM
Helis, DL
Huang, HZ
Huang, RG
Ianni, A
Imbert, L
Johnston, J
Juillard, A
Karapetrov, G
Keppel, G
Khalife, H
Kobychev, VV
Kolomensky, Yu G
Konovalov, SI
Liu, Y
Loaiza, P
Ma, L
Madhukuttan, M
Mancarella, F
Mariam, R
Marini, L
Source :
JOURNAL OF INSTRUMENTATION, vol 16, iss 2
Publication Year :
2021
Publisher :
eScholarship, University of California, 2021.

Abstract

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

Details

Database :
OpenAIRE
Journal :
JOURNAL OF INSTRUMENTATION, vol 16, iss 2
Accession number :
edsair.od.......325..9538e631479f73dd5cff44337a12fd86