Back to Search
Start Over
National Performance Benchmarks for Modern Diagnostic Digital Mammography: Update from the Breast Cancer Surveillance Consortium
- Source :
- Radiology, vol 283, iss 1
- Publication Year :
- 2017
- Publisher :
- eScholarship, University of California, 2017.
-
Abstract
- Purpose To establish contemporary performance benchmarks for diagnostic digital mammography with use of recent data from the Breast Cancer Surveillance Consortium (BCSC). Materials and Methods Institutional review board approval was obtained for active or passive consenting processes or to obtain a waiver of consent to enroll participants, link data, and perform analyses. Data were obtained from six BCSC registries (418 radiologists, 92 radiology facilities). Mammogram indication and assessments were prospectively collected for women undergoing diagnostic digital mammography and linked with cancer diagnoses from state cancer registries. The study included 401 548 examinations conducted from 2007 to 2013 in 265 360 women. Results Overall diagnostic performance measures were as follows: cancer detection rate, 34.7 per 1000 (95% confidence interval [CI]: 34.1, 35.2); abnormal interpretation rate, 12.6% (95% CI: 12.5%, 12.7%); positive predictive value (PPV) of a biopsy recommendation (PPV2), 27.5% (95% CI: 27.1%, 27.9%); PPV of biopsies performed (PPV3), 30.4% (95% CI: 29.9%, 30.9%); false-negative rate, 4.8 per 1000 (95% CI: 4.6, 5.0); sensitivity, 87.8% (95% CI: 87.3%, 88.4%); and specificity, 90.5% (95% CI: 90.4%, 90.6%). Among cancers detected, 63.4% were stage 0 or 1 cancers, 45.6% were minimal cancers, the mean size of invasive cancers was 21.2 mm, and 69.6% of invasive cancers were node negative. Performance metrics varied widely across diagnostic indications, with cancer detection rate (64.5 per 1000) and abnormal interpretation rate (18.7%) highest for diagnostic mammograms obtained to evaluate a breast problem with a lump. Compared with performance during the screen-film mammography era, diagnostic digital performance showed increased abnormal interpretation and cancer detection rates and decreasing PPVs, with less than 70% of radiologists within acceptable ranges for PPV2 and PPV3. Conclusion These performance measures can serve as national benchmarks that may help transform the marked variation in radiologists' diagnostic performance into targeted quality improvement efforts. © RSNA, 2017 Online supplemental material is available for this article.
- Subjects :
- Adult
Breast Neoplasms
Sensitivity and Specificity
Medical and Health Sciences
Age Distribution
Clinical Research
Breast Cancer
80 and over
Humans
Mass Screening
Registries
Early Detection of Cancer
Aged
Cancer
screening and diagnosis
Breast Cancer Surveillance Consortium
Prevention
Middle Aged
Benchmarking
Detection
Nuclear Medicine & Medical Imaging
Good Health and Well Being
Biomedical Imaging
Female
Mammography
4.2 Evaluation of markers and technologies
Subjects
Details
- Database :
- OpenAIRE
- Journal :
- Radiology, vol 283, iss 1
- Accession number :
- edsair.od.......325..b2f7cb773b4f54fbe2567ec52d952ae3