Back to Search Start Over

Rationale and design of the EU-CERT-ICD prospective study: comparative effectiveness of prophylactic ICD implantation

Authors :
Zabel, Markus
Sticherling, Christian
Willems, Rik
Lubinski, Andrzej
Bauer, Axel
Bergau, Leonard
Braunschweig, Frieder
Brugada, Josep
Brusich, Sandro
Conen, David
Cygankiewicz, Iwona
Flevari, Panagiota
Taborsky, Milos
Hansen, Jim
Hasenfuss, Gerd
Hatala, Robert
Huikuri, Heikki V
Iovev, Svetoslav
Kaeaeb, Stefan
Kaliska, Gabriela
Kasprzak, Jaroslaw D
Luethje, Lars
Malik, Marek
Novotny, Tomas
Pavlovic, Nikola
Schmidt, Georg
Shalganov, Tchavdar
Sritharan, Rajeeva
Schloegl, Simon
Traykov, Vassil
Tuinenburg, Anton E
Velchev, Vasil
Vos, Marc A
Willich, Stefan N
Friede, Tim
Svendsen, Jesper Hastrup
Merkely, Bela
Seegers, J
Munoz-Exposito, P
Tichelbacker, T
Kirovo, A
Joerss, K
Macken, J
Misdaq, M
Rudolph, K
Mueller, A
Dommasch, M
Sinnecker, D
Sinner, M
Dissmann, R
Burmester, U
Behrens, S
Gregor, M
Stefanow, S
Rueb, N
Wolpert, C
Bimmel, D
Lieberz, C
Maier, L
Schwinger, R
Blaschke, F
Pieske, B
Groenefeld, G
Klein, G
Gardiwal, A
Szeplaki, G
Perge, P
Nossan, J Szavits
Rotkvic, L
Manola, S
Vinter, O
Benko, I
Brusic, S
Avdovic, E
Klasan, M
Bakotic, Z
Anic, A
Kowalczyk, E
Kucejko, T
Czechowska, A
Wybor, K
Ptaszynski, P
Qavoq, H
Guzik, P
Krauze, T
Sterlinski, M
Svetlosak, M
Martinek, J
Thamsborg, K
Schloett-Hyldelund, IM
Laage-Petersen, J
Vandenberk, B
van Soest, S
Giesebart, S
Kozak, M
Galuszka, J
Wijers, S
Dunnink, A
Sprenkeler, D
Arbelo, E
Trucco, E
Vidorreta, S
Kentta, T
Pelli, A
Huikuri, P
Koski, P
Karlsson, H
Ersgaard, D
Platonov, P
Klingenheben, T
Scharfe, M
Reinhold, T
Cree, M
Hnatkova, K
Gerhardt, J
Rizas, K
Hamm, W
Roever, C
Harden, M
Kessel, B
Berg, A
Apel, S
Walker, F
Kirchhof, N
Goerlitz, A
Molitor, A
Heinrich, J
Annetzberger, S
Fuchs, B
Landwehr, A
Merk, A
Wilke, A
Hennecke, C
Mansch, R
Publication Year :
2019
Publisher :
WILEY PERIODICALS, INC, 2019.

Abstract

AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value. METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers. ispartof: ESC HEART FAILURE vol:6 issue:1 pages:182-193 ispartof: location:England status: published

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.od......1131..72b6e1f37f9ea9b590fdef54a306e7dc