Back to Search
Start Over
A digitizer with exceptional accuracy for use in prosthetics research: a technical note
- Source :
- Journal of rehabilitation research and development. 40(2)
- Publication Year :
- 2004
-
Abstract
- A mechanical digitizer was developed for use in prosthetics research where measurements of small differences in shape are of interest. Root-mean-square error was 0.075 mm in the radial direction, 0.05 degrees in the tangential direction, and 0.1 mm in the vertical direction. The system has potential use for time-dependent assessment of changes in socket and residuum cast shape, assessment of socket fabrication systems, and development of accurate prosthetic finite element models.
Details
- ISSN :
- 07487711
- Volume :
- 40
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Journal of rehabilitation research and development
- Accession number :
- edsair.pmid..........043e983924f33859dda5fc596321c247