Back to Search Start Over

[Teamwork for cardiac imaging: coronary computed tomography angiography and low-dose radiation exposure: a cardiology center experience]

[Teamwork for cardiac imaging: coronary computed tomography angiography and low-dose radiation exposure: a cardiology center experience]

Authors :
Massimo, Magnacca
Rosa, Poddighe
Jacopo, Del Meglio
Alessio, Lilli
Marco Tullio, Baratto
Maria Laura, Canale
Carlo, Tessa
Luca, Salvatori
Alessandra, Niespolo
Claudio, Vignali
Giancarlo, Casolo
Source :
Giornale italiano di cardiologia (2006). 18(4)
Publication Year :
2017

Abstract

Multidetector coronary computed tomography angiography (CCTA) is increasingly used for noninvasive imaging of the coronary arteries. Radiation exposure, however, is a potential limitation to a more extensive use of this imaging modality. We aimed to demonstrate that a professional teamwork approach, including a cardiologist and a radiologist in performing CCTA, may allow to obtain best quality exams with very low radiation doses.A total of 998 consecutive patients underwent CCTA in accordance with the most recent guidelines. The following procedures were undertaken to reduce the radiation dose: (a) preliminary cardiological evaluation to check for CCTA eligibility; (b) optimized heart rate control with beta-blockers and/or ivabradine; and (c) the use of nonstandardized computed tomography protocols and algorithms for dose reduction.All the patients underwent a preliminary cardiological evaluation; 89% of them were pretreated with oral or intravenous beta-blockers and/or ivabradine; 806 patients (81%) were scanned by means of prospective gating, which allowed a radiation dose exposure of 161 ± 68.64 mGy; 192 patients (19%) underwent a retrospective gating protocol, with a radiation dose exposure of 1135.15 ± 485.87 mGy. In 13 patients (1%) CCTA was uninterpretable because of artifacts. Exam quality was not affected by the use of low-dose computed tomography scanning. Coronary calcium score and/or left ventricular functional analysis were never performed.The preliminary selection and preparation of patients and optimized scanner utilization allow a substantial reduction in radiation dose for most of the patients submitted to CCTA without affecting image quality. In our experience, a team approach was necessary to allow a "low-dose learning curve" and a progressive reduction in radiation doses administered to patients by means of the prospective gating protocol.

Details

ISSN :
18276806
Volume :
18
Issue :
4
Database :
OpenAIRE
Journal :
Giornale italiano di cardiologia (2006)
Accession number :