Back to Search
Start Over
Efficient materially nonlinear \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu$$\end{document}μFE solver for simulations of trabecular bone failure
- Source :
- Biomechanics and Modeling in Mechanobiology
- Publication Year :
- 2019
- Publisher :
- Springer Berlin Heidelberg, 2019.
-
Abstract
- An efficient solver for large-scale linear \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu \hbox {FE}$$\end{document}μFE simulations was extended for nonlinear material behavior. The material model included damage-based tissue degradation and fracture. The new framework was applied to 20 trabecular biopsies with a mesh resolution of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${36}\,{{\upmu }\hbox {m}}$$\end{document}36μm. Suitable material parameters were identified based on two biopsies by comparison with axial tension and compression experiments. The good parallel performance and low memory footprint of the solver were preserved. Excellent correlation of the maximum apparent stress was found between simulations and experiments (\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$R^2 > 0.97$$\end{document}R2>0.97). The development of local damage regions was observable due to the nonlinear nature of the simulations. A novel elasticity limit was proposed based on the local damage information. The elasticity limit was found to be lower than the 0.2% yield point. Systematic differences in the yield behavior of biopsies under apparent compression and tension loading were observed. This indicates that damage distributions could lead to more insight into the failure mechanisms of trabecular bone.
- Subjects :
- Trabecular bone
Original Paper
Yield strength
Micro finite element
Biopsy
Finite Element Analysis
Models, Biological
Bone and Bones
Elasticity
Biomechanical Phenomena
Fractures, Bone
Nonlinear Dynamics
Nonlinear material
Cancellous Bone
Humans
Computer Simulation
Stress, Mechanical
Algorithms
Software
Subjects
Details
- Language :
- English
- ISSN :
- 16177940 and 16177959
- Volume :
- 19
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Biomechanics and Modeling in Mechanobiology
- Accession number :
- edsair.pmid..........f9011562747611cc76fbc7b7ce9799f0