Back to Search
Start Over
Clinical usefulness of technetium-99m-HMPAO-labeled leukocyte scan in prosthetic vascular graft infection
- Source :
- Europe PubMed Central
- Publication Year :
- 1998
- Publisher :
- SOC NUCLEAR MEDICINE INC, 1998.
-
Abstract
- The infection of a prosthetic vascular graft (PVGI), although rare, is the most severe complication in reconstructive vascular surgery. The early diagnosis of this complication reduces the death rate from surgery. Aortofemoral graft infections differ clinically from peripheral graft infections in significant ways. The aim of this article is to evaluate separately the reliability of the 99mTc-HMPAO-labeled leukocyte scan or white blood cell count (WBC) in the early detection of both aortofemoral and peripheral graft infections.One hundred sixty-two WBCs were performed on 129 consecutive patients with suspected aortofemoral (122 scans) and peripheral (40 scans) graft infection and in a 12-patient control group. Patients with suspected PVGI were categorized into three groups on the basis of their signs and symptoms on readmission: (a) patients with specific signs of graft infection (Group A); (b) patients with nonspecific signs of graft infection (Group B); and (c) patients with anastomotic aneurysms (Group C). Gram's stains of the perigraft exudate and graft cultures were performed and used as the gold standard in patients who underwent surgery. An 18-mo clinical follow-up was done to assess the presence or absence of graft infection in patients who did not have surgery.In patients with suspected aortofemoral graft infections, the overall sensitivity, specificity and accuracy of WBCs (Groups A, B, C) were 100%, 92.5% and 97.5%, respectively, whereas sensitivity, specificity and accuracy calculated in the patients with nonspecific signs of graft infection (Groups B, C) were 100%, 92.3% and 96.9%, respectively. In patients with suspected peripheral graft infections, sensitivity, specificity and accuracy were 100%.The white blood cell scan seems a reliable diagnostic method for early diagnosis of PVGI, and it is more useful in aortofemoral graft infections.
- Subjects :
- Male
leukocyte scan
Prosthesis-Related Infections
Time Factors
technetium-99m-hmpao-labeled
Polyethylene Terephthalates
vascular graft
Reproducibility of Results
Middle Aged
Sensitivity and Specificity
infection
Blood Vessel Prosthesis
Leukocyte Count
Technetium Tc 99m Exametazime
Case-Control Studies
Isotope Labeling
Leukocytes
Humans
Female
Radiopharmaceuticals
Radionuclide Imaging
Polytetrafluoroethylene
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Europe PubMed Central
- Accession number :
- edsair.pmid.dedup....7028d4b6e6e489cf4fb9b5ff9e0bb649